Overload Warning
Please do not add any item that exceeds the maximum capacity of the scale.
When the display shows "- - - - - ", remove the item to avoid damage to the load
cell and scale.

3.2 BATTERY OPERATION

• The rechargeable battery will operate continuously for between 20 and
30 hours before requiring recharging.
• To charge the battery, plug the charger unit into the socket as marked
C O P Y
on the rear of the scale. Plug the charger into the mains power supply
and wait until the LED on the charger shows green. The battery is now
fully charged.
• Charging time for a completely discharged battery is approximately 16
hours. A full battery pack is recommended to keep the scale
continuously operational.
• Only use the charger as supplied with the unit.
• The scale will automatically power down after 30 minutes of non use to
further protect the battery.
• To replace the battery, turn the locking screw on the battery cover 90
degrees clockwise and lift open the cover. Disconnect and remove the
old battery and replace with a new one.
• Contact your dealer for a replacement battery.