Installation
Product Overall Dimension
01
02
03
04
05
06
07
NOTE
• The measurements in the above table may differ, depending on the measuring method.
• For built-in installation, see the Installation Manual.
26
English
BRR13R121*/BRR3GR121*
Model
FIXED TYPE
01 *
15 RECOMMEND
02
115°
03
225
04
765
05
509,5
06
5
07
1120
(unit : mm)
NOTE
• The specified energy consumption is
based on the condition of a 15 mm gap
from cabinet to rear of product. The
product will work properly even with a
gap which is less than 15 mm, however
it consumes slightly more energy.
• We recommend using a cabinet that
is 18 mm thick with hinges less than
20 mm thick.
Ventilation system of the cabinet
As shown in the figure, the air entering the refrigerator circulates along the ventilation
path (see the arrow direction) of the cabinet. The cabinet must have at least 360 cm
example WxH: 480 mm x 75 mm) of space both for the air inlet and air outlet. Also, the
cabinet must have a rear vent of at least 360 cm
space at the rear bottom.
Air inlet
A
B
1
1
1
1
1
1
1
1
Air outlet
A
B
C
2
(for
(for example WxH: 480 mm x 75 mm) of
2
1
360 cm
2
The air inlet must be positioned in one of
the examples below, or a similar position,
depending on your cabinet type.
A. A ventilation hole included in the
cabinet.
B. A cabinet with feet.
The air outlet must be positioned in one of
the examples below, or a similar position,
depending on your cabinet type.
A. Immediately above the refrigerator
with an optional vent grille
B. Close to the cabinet ceiling
C. Above the refrigerator with a
separately built-in vent
CAUTION
Regardless of the cabinet design, the air
ventilation system must not be blocked by
any kind of installation.
English