Herunterladen Inhalt Inhalt Diese Seite drucken

Monitoring The Body Temperature; Cleaning And Disinfecting; Battery Replacement; Guarantee - Microlife PT200 Bedienungsanleitung

Bluetooth patch thermometer
Inhaltsverzeichnis

Werbung

3. Take one adhesive patch, remove the protective film and place
the device right in the middle of the patch 6. The battery
compartment 4 side should be stuck on the patch. The
measuring sensor 1 needs to be in contact with the skin and
as close as possible to the armpit.
4. Place the device with the adhesive patch directly on the skin
below the armpit 7.
5. Lower the arm and wait around 15 minutes until the temperature
rises to the body temperature level.
6. The temperature display will appear on the smartphone.
7. Press and hold the ON/OFF button 2 for 3 seconds to turn off
the device; otherwise the device will automatically switch off
after approx. 30 minutes, when removed from the body.
To keep a good connection, avoid distances above 5 m
between the device and the smartphone.
Obstacles (e.g. walls) may weaken the connection.
NOTE:
 Regularly check for sufficient skin contact of the device, in order
to avoid measurement errors.
 Sudden movements or low battery power may lead to inaccu-
rate measurement results.
 The adhesive patches are for single use only – do not use them
repeatedly. Only use them in smooth and undamaged condition.
 Don't use the thermometer in high humidity environments.
 Doctors recommend rectal measurement for newborn infants
within the first 6 months, as all other measuring methods might
lead to ambiguous results.
 Readings from different measuring sites should not be
compared as the normal body temperature varies by
measuring site and time of day, being highest in the evening
and lowest about one hour before waking up.
Normal body temperature ranges:
- Axillar: 34.7 - 37.3 °C / 94.5 - 99.1 °F
- Oral: 35.5 - 37.5 °C / 95.9 - 99.5 °F
- Rectal: 36.6 - 38.0 °C / 97.9 - 100.4 °F
- Microlife PT 200: 34.7 - 37.3 °C / 94.5 - 99.1 °F

5. Monitoring the body temperature

Monitor the body temperature for up to 72 hours, once the device
is connected to the App. A measurement is taken every 5 seconds
and transferred to the App. You can also track the temperature
trend of the past hours and the data of previous measurements.
3
If the device is disconnected from the App, the device will
save one measurement every minute and send the stored
results to the App, once Bluetooth

6. Cleaning and Disinfecting

Use an alcohol swab or cotton tissue moistened with alcohol (70%
Isopropyl) to clean the thermometer casing and the measuring
sensor. Ensure that no liquid enters the interior of the device.
Never use abrasive cleaning agents, thinners or benzene for
cleaning and never immerse the device in water or other cleaning
liquids. Take care not to scratch the measuring sensor.

7. Battery Replacement

This device is supplied with one lithium battery type CR2032. The
battery needs replacing, when the power indicator 3 is blinking
red and a notification on the smartphone App is shown.
Remove the battery cover 4 by using a coin and rotate clockwise
to open. Insert the new battery with the + at the top 5. Then posi-
tion the battery cover and rotate it counterclockwise to close.
Batteries and electronic devices must be disposed of in
accordance with the locally applicable regulations, not with
domestic waste.

8. Guarantee

This device is covered by a 5 year guarantee from the date of
purchase. The guarantee is valid only on presentation of the guar-
antee card completed by the dealer (see back) confirming date of
purchase or the receipt.
 The guarantee covers the device. The battery and packaging
are not included.
 Opening or altering the device invalidates the guarantee.
 The guarantee does not cover damage caused by improper
handling, a discharged battery, accidents or non-compliance
with the operating instructions.
Please contact Microlife-service.
is connected again.
®

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pt 200

Inhaltsverzeichnis