D749MA CHARACTERISTICS
TIMER-OPERATED OPENING AND CLOSING CYCLES
The opening/closing of the automation can be controlled by means of a timer that has a free N.O.
output contact (relay). The timer must be connected to terminals 4 - 6 (OPEN/CLOSE button) and
can be programmed so that, at the desired opening time, the relay contact closes until the desired
closing time (when the timer's relay contact opens, enabling the automatic closing of the gate).
Note: the automatic closing function must be enabled by setting Dip-switch no. 1 to ON).
BATTERY CHARGER BOARD (INTEGRATED)
If the battery is connected the automation will operate in any case if there is no mains power
supply. If the voltage drops below 11.3 Vdc, the automation ceases to operate (the control unit
remains fed); whereas, when the voltage drops below 10.2 Vdc, the card completely disconnects
the battery (the control panel is no longer fed).
OBSTACLE DETECTION
If the obstacle detection function (which can be set through trimmer FR) is activated during an
opening manoeuvre, the gate closes approx. 20 cm., if it is activated during a closing manoeuvre,
the gate opens all the way .
WARNING: the control panel logics may interpret mechanical friction as an obstacle.

DIAGNOSTICS LED

DL1 - Red
PEDESTRIAN button LED signal
DL2 - Red
OPEN/CLOSE button LED signal
DL3 - Green
STOP button LED signal
DL4 - Green
CLOSE button LED signal
DL5 - Green
PHOTOCELL LED signal
DL6 - Green
SENSITIVE EDGE LED signal
LED - DL7
Apart from highlighting the presence of the battery, LED DL7 displays any mistakes with a series
of pre-set flashes in various colours:
Key:
led
always
on;
led flashing;
always on (green):
always on (yellow):
1 flash every 4 seconds (green): fully-charged battery, no main voltage;
1 flash every 4 seconds (yellow): external power, charger disabled;
1 flash every 2 seconds (red):
fast flashing (red):
LED - DL8
The DL8 LED indicates mistakes in the board logic with a series of pre-set flashes in different
colours:
Key:
led
always
on;
led flashing;
1 flash every 4 seconds (green): normal operation;
fully-charged battery, main voltage present;
battery charging;
Check the main voltage;
low battery;
Charge the battery, replace the battery;
faulty battery;
Replace the battery;