NOTE
NOTE
Y axis and tilt symbols
Use
button to
are displayed flashing
confirm set value for
X axis
The laser levels itself
Use
button to
horizontally
adopt set value for
Y axis
During and for 30 seconds after the horizontal levelling the laser detects vib-
rations, horizontally levels itself again and sets the default percentage values.
The TILT alarm function is switched on after 30 seconds. The laser detects a large
vibration and triggers the warning message C01. With the Primus 2 H2N+, small
vibrations are detected and corrected for by the automatic feature, so that the exact
set tilt is retained for a longer period.
The TILT X/Y axis function is active. The following functions can be invoked:
Use the
button to invoke the TILT function again and change the percen-
tage values for the X/Y axis.
Use the
button to switch to MANUAL operating mode (Chapter 7.2). The
set tilt values are retained but do not appear in the display.
Use the
button to exit the operating mode, switch off the laser.
f The
buttons are equipped with comfort functions for fast and precise setting
of the percentage values. For a description, see Chapter 8.2, Page 37.
f The most recently set tilt values are saved when the laser is switched off and the
next time the TILT function is started, these set values are shown in the display as
default values.
Accept 0.00 % value with the button or set
a value, e.g. +8 %, for Y axis using the comfort
functions of the
buttons (see Page 37)
The percentage values entered for the X and Y
axis are set