5
Installation and
connection

Contents of package

c o n n e c t i o n
I n s t a l l a t i o n a n d
After unpacking all parts, check for any
damage in transit.
If you have any complaints, contact the
dealer from whom you purchased the
appliance or our after-sales service.
~ "Customer service" on page 34
The delivery consists of the following
parts:
Built-in appliance
Interior fittings (depending on model)
Bag containing installation materials
User manual
Installation instructions
Customer service booklet
Warranty enclosure
Information on the energy
consumption and noises

Technical specifications

Refrigerant, cubic capacity and further
technical specifications can be found on
the rating plate.
~ "Getting to know your appliance"
on page 26

Installing the appliance

Installation location
The more refrigerant an appliance
contains, the larger the room must be
in which the appliance is situated.
Leaking refrigerant can form
a flammable gas-air mixture in rooms
which are too small.
Installation and connection en
The room must be at least 1 m³ per 8 g
of refrigerant. The amount of refrigerant
in your appliance is indicated
on the rating plate inside the appliance.
~ "Getting to know your appliance"
on page 26
The weight of the appliance may be up
to 73 kg depending on the model.
Permitted room temperature
The permitted room temperature
depends on the climatic class of the
appliance.
Information on the climatic class can
be found on the rating plate.
~ "Getting to know your appliance"
on page 26
Climatic
Permitted room temperature
category
+10 °C ... 32 °C
SN
N
+16 °C ... 32 °C
ST
+16 °C ... 38 °C
+16 °C ... 43 °C
T
The appliance is fully functional within
the permitted room temperature.
If an appliance of climatic class SN is
operated at colder room temperatures,
the appliance will not be damaged up to
a room temperature of +5 °C.

Cavity depth

A cavity depth of 56 cm
is recommended for the appliance.
If the cavity depth is smaller – at least
55 cm – the energy consumption
increases slightly.