IMPORTANT REMARKS
For any installation problems please contact V2 ELETTRONICA
TEL. (+39) 01 72 81 24 11
V2 ELETTRONICA has the right to modify the product
without previous notice; it also declines any responsibility
to damage or injury to people or things caused by
improper use or wrong installation.
Please read this instruction manual very carefully
before installing and programming your PD1 control unit.
•
This instruction manual is only for qualified technicians,
who specialize in installations and automations.
•
The contents of this instruction manual do not concern
the end user.
•
Every programming and/or every maintenance service
should be done only by qualified technicians.
The PD1 control unit can drive one or more
electromechanical actuators for the automation of swing
doors and swing gates. Any other utilization is not in
specification.
AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE
WITH THE EUROPEAN REGULATIONS IN FORCE:
EN 60204–1 (Machinery safety. electrical equipment of
machines, part 1: general rules)
EN 12445
(Safe use of automated locking devices,
test methods)
EN 12453
(Safe use of automated locking devices,
requirements)
•
The installer must provide for a device
(es. magnetotermical switch) ensuring the omnipolar
sectioning of the equipment from the power supply.
The standards require a separation of the contacts of at
least 3 mm in each pole (EN 60335-1).
•
Installation requires mechanical and electrical skills,
therefore it shall be carried out by qualified personnel
only, who can issue the Compliance Certificate
concerning the whole installation (EEC Machine
Directive 89/392, Annex IIA).
•
The automated vehicular gates shall comply with the
following rules: EN 12453, EN 12445, EN 12978 as
well as any local rule in force.
•
Also the automation upstream electric system shall
comply with the laws and rules in force and be carried
out workmanlike.
•
The door thrust force adjustment shall be measured by
means of a proper tool and adjusted according to the
max. limits, which EN 12453 allows.
•
We recommend to make use of an emergency button, to
be installed by the automation (connected to the
control unit STOP input) so that the gate may be
immediately stopped in case of danger.
•
Please connect the ground wire of motors to the
grounding.
CONFORMITY TO REGULATIONS
V2 ELETTRONICA SPA declares that PD1 is in
conformity with the provisions of the followings 93/68/EEC,
73/23/EEC, and with the standards referenced here below:
EN 60335–1: Electrical safety
EN 50081–1, EN 50081–2: Electromagnetic compatibility
Racconigi, 15 / 10 / 01
V2 ELETTRONICA SPA legal representative.
A.Livio Costamagna
DESCRIPTION OF THE CONTROL UNIT
The digital station PD1 is an innovative V2 ELETTRONICA
product that guarantees a safe and reliable automation of
one- and two-shutter gates.
The design of PD1 has been designed to realize a product
that meets all kind of requirements, with a highly versatile
station that satisfies all the necessary requirements for a
functional and efficient installation.
PD1 is provided with a display that, not only makes
programming simple, but also allows a continuous
monitoring of the input statuses; in addition, thanks to a
menu structure, the working schedule and the operation
logic can be set easily.
With regard to the European regulations concerning
electrical safety and electromagnetic compatibility
(EN 60335-1, EN 50081-1, and EN 50082-1), PD1 is
characterized by a complete isolation between the digital
circuit and the power circuit.
Other characteristics:
•
Automatic relay zero-current switching control.
•
Wave choke power adjustment.
•
Warning light showing the status of the gate.
•
Programmable logic auxiliary relay for courtesy lights or
other use.
A specially provided plug-in connector allows insertion of a
MT433 series receiver, having a high sensitivity super
heterodyne architecture.
16