B (NO)
Type of protection:
IP65 in accordance with DIN EN
60529 / IEC 60529 with correctly
connected and installed device
socket, e.g. Bürkert Type 2508
6.2.
Application conditions
Allowable temperatures
Ambient temperature:
max. +55 °C
Permitted medium temperature depending on coil and seal
material:
Seal material
FKM
EPDM
NBR
12
english
6.3.
conformity
CE mark conforms to EMC Directive 2004/108/EEC (only
if cables, plugs and sockets connected correctly).
6.4. rating plate description
Fig. 1:
Location of the rating plate
14
english
Medium temperature
0 °C ... +90 °C
-30 °C ... +90 °C
-10 °C ... +80 °C
Rating plate
Permitted media depending on seal material:
Seal material
FKM
Per-solutions, hot oils without addi-
tives, diesel and heating oil without
additives, detergent solution
EPDM
Oil and grease-free liquids, cold and
hot water
NBR
Cold and warm water
Operating duration
Unless otherwise indicated on the rating plate, the solenoid
system is suitable for continuous operation.
Important information for functional reliability during
continuous operation!
If switched on for a long period, it is recommended
to activate the valve 1-2 per day.
Service life
High switching frequency and high pressures reduce the
service life.
6.4.1.
rating plate
Example:
Orifice
Operating
prinziple
Type
5282EV A 25 EPDM MS
G1 1/4 P N 0,2 - 16 bar
230V
00210535
Article number
Manufacturer-Code
Voltage, frequency, power
consumption
Connection thread, nominal
pressure
Type 5282 EV
Permitted media
english
13
Seal material
Housing material
50-60Hz
8W
W17 LU
english
15