hose is not damaged (crushed, bent,
en
twisted, taught).
it
►2.17.If the smell of gas is perceived,
switch the appliance off immediately,
de
close the gas cylinder, disconnect the
es
mains plug and then contact the after-
fr
sales assistance.
►2.18.If the gas hose must be replaced,
nl
only use the flexible type suitable for
pt
the pressure used, referring to national
regulations. The gas hose must measure
da
1,5 m.
fi
►2.19.When the appliance is controlled
by a room thermostat (optional article),
no
the heater can switch back on at any time
sv
i.e. when the temperature drops below the
pl
threshold set.
►2.20.When it is not used, disconnect the
ru
heater from the network plug, close the
cs
gas supply, disconnect the gas hose from
the heater and plug the gas inlet on the
hu
heater.
sl
►2.21.Have the after-sales assistance
check correct functioning of the heater
tr
at least once a year and/or according to
hr
need.
lt
►►3. TYPE OF FUEL
lv
Use category I3B/P gas only.
et
►►4. CONNECTION AND
ro
REPLACEMENT OF THE GAS
sk
CYLINDER
The gas cylinder must be replaced in the
bg
open air, away from heat sources, in an
uk
atmosphere without flames.
bs
Only the following accessories must be
used for connection of the gas cylinder to
el
the heater:
zh
•Liquid gas flexible pipe.
•Liquid gas pressure regulator complete
with safety valve.
CHECK THE INTEGRITY OF THE GAS
SUPPLY PIPE. IF THE GAS HOSE
MUST BE REPLACED, ONLY USE THE
FLEXIBLE TYPE SUITABLE FOR THE
PRESSURE USED, REFERRING TO
NATIONAL REGULATIONS.
►To connect the heater to the gas
cylinder:
ATTENTION:
ALL
SINISTRAL, I.E. THEY ARE TIGHTENED
IN AN ANTI-CLOCKWISE DIRECTION.
►4.1.Screw the gas hose to the heater
fitting (Pic. 4).
►4.2.Install the pressure regulator on the
gas cylinder. Make sure there is a gasket
present on the regulator (if envisioned by
the type of connection) (Pic. 5).
►4.3.Connect the gas hose to the
pressure regulator (Pic. 6).
►4.4.Open the gas cylinder cock (Pic. 7).
►4.5.Press the regulator release button
(Pic. 8). Check tightness of fittings
using soapy water: bubbles indicate a
gas leak (Pic. 9). Several gas cylinders
can be fitted together to obtain greater
autonomy. The use of 30 kg gas cylinders
is
recommended,
capacity of 33 kW. Over the power of
33 kW use gas cylinders with greater
capacity. The use of gas cylinders with
suitable capacity is recommended in
order to prevent problems due to lack
of gasification of the fuel. The correct
functioning pressure (see data plate
applied to the heater) is given by the
regulator supplied or an equivalent model.
►►5. CONNECTION TO THE
MAINS ELECTRICITY
CHECK YOUR ELECTRIC SYSTEM IS
EARTHED CORRECTLY.
Before connecting the heater to the mains
electricity, make sure that the power
supply voltage and frequency are correct
(see data plate applied to the heater). The
connection to the mains electricity (Pic.
10) must be made in compliance with the
National Standards in force.
THREADING
IS
up
to
heating