Replace the main fuse:
1. Unplug the mains cable from the output socket.
2. Open the fuse holder and replace the fuse with one of the same type. The fuse rating is listed on
the rating label.
SPECIFICATIONS:
•
Multi-color
•
12 Rotating gobo patterns
•
Gobo shake function
•
DMX-512/4 channels
•
Standalone auto mode
•
Sound activated
•
Master/slave function
•
Menu display
•
Fan-cooled
•
Adjustable mounting bracket
•
Lamp: ELC 24V/250W GX5.3 (included)
•
Power supply: 230 V AC, 50/60 Hz
•
Dimensions (WxHxD): 365x195x365mm
•
Weight: 4.3kg
TROUBLESHOOTING:
Problem
One or more fixtures are
completely dead.
Fixture is working correctly
but no light output.
Fixtures reset correctly
but all respond erratically
or not at all to controller.
Fixtures reset correctly but
some respond erratically
or not at all to controller.
DL-QUAKE250_A5.indd 6
Probable cause
No power to the fixture.
Main fuse blown.
Broken or worn out lamp.
Controller not connected.
XLR pin-out of controller does
not match pin-out of first fixture
on link (polarity is reversed).
Bad data link connection.
Data link not terminated with
120 Ohm termination plug.
Incorrect fixture addressing.
One of the fixtures is
transmitting as a master.
One of the fixtures is defective.
6
Solution
Make sure that cables are plugged
in and power is switched on.
Replace fuse.
Install new lamp.
Connect controller.
Install a phase-reversing cable
between controller and first fixture
on link.
Inspect connections and cables.
Correct poor connections. Repair
or replace damaged cables.
Insert termination plug in output of
last fixture on link.
Check DMX addresses.
Check all fixture settings.
Bypass one fixture at a time (unplug
both DMX connectors and connect
them directly together) until normal
operation is regained. Defective
fixture has to be serviced by a
technician.
2009.9.1 9:33:30 AM