NOTE: Perform Air Removal and Pressure (Torque) Adjustment:
1.
during initial operation or start-up
2.
when connecting a different wrench to the pump
3.
when changing torque value (pressure adjustment only).

5.0 MAINTENANCE

5.1 Changing the Oil
Completely drain the reservoir after every 250 hours of operation.
If pump is operated in very dusty areas or at high temperatures,
drain and refill more frequently.
1.
Remove the breather cap from reservoir.
2.
Tip the pump until all old oil has drained out.
3.
Add new hydraulic oil through breather opening until the oil
level is one inch below the vent/fill opening. Reservoir capacity
is 1 gal. [3,7 L].
4.
Replace the breather cap.
5.
DISPOSE OF USED OIL PROPERLY.
5.2 Cleaning the Muffler
When the pump is run for long periods of time, ice may form on the
muffler element and must be removed. To clean the muffler,
unscrew the front plate and remove any debris.
5.3 Cleaning the Air-Filter Lubricator
Inspect the air-filter lubricator frequently to detect crazing,
cracking, or damage. Replace damaged bowls.
Keep the filter bowl clean to maintain filtering efficiency. Turn drain
valve (G) clockwise from bottom to drain any bowl accumulation.
(See Figure 6.)
Pump will not start.
Motor stalls under load.
Pump fails to build pressure.
Pump builds less than full pressure.
Wrench will not retract.
Low oil flow rate.
Problem
A visible coating of dirt or condensate on the filter element or an
excessive air pressure drop indicates that cleaning is necessary.
Depressurize the unit before removing bowl for cleaning.
CAUTION:
Clean filter bowl with household soap
only.

6.0 TROUBLESHOOTING

Only qualified hydraulic technicians should service the pump or
system components. The following information is intended to be
used as an aid in determining if a problem exists. For repair service
contact your Enerpac Authorized Service Station.
Possible Cause
Air turned off or air line blocked.
Low air pressure.
External leak in system.
Internal leak in system.
Internal leak in valve.
Internal leak in system component.
Pump lost prime.
Relief valve set low.
External system leak.
Internal leak in pump.
Internal leak in valve.
Internal leak in system component
Valve malfunction.
Return flow line restricted or blocked.
Inadequate air supply.
Dirty air filter.
Clogged inlet filter.
4