Herunterladen Inhalt Inhalt Diese Seite drucken

Measuring Functions - Bosch GLM 40 Professional Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für GLM 40 Professional:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Apply the measuring tool to the point at which you want to start the measurement (e.g.
wall).
Note: If the measuring tool has been switched on using the on/off button (5) [ ], briefly
press the measuring button (2) [ ] to switch the laser on.
To initiate the measurement, briefly press the measuring button (2) [ ]. Then the laser
beam is switched off. To switch the laser beam on again, briefly press the measuring but-
ton (2) [ ]. To initiate a further measurement, briefly press the measuring button
(2) [ ] again.
Do not direct the laser beam at persons or animals and do not stare into the laser
u
beam yourself (even from a distance).
In the continuous measurement mode, the measurement begins immediately upon
switching on the function.
Note: The measured value typically appears within 0.5 seconds and no later than
4 seconds. The duration of the measurement depends on the distance, the lighting con-
ditions and the reflective properties of the target surface. Upon completion of the meas-
urement, the laser beam is automatically switched off.

Measuring functions

Measuring length
For length measurements, repeatedly press button (4) [Func] until the indicator for
length  appears on the display (1).
To switch on the laser beam, briefly press the measuring button (2) [ ].
To measure, briefly press the measuring button (2) [ ]. The meas-
ured value will be shown at the bottom of the display.
Repeat the above-mentioned steps for each subsequent measure-
ment. The last three measured values are shown on the display. The
last measured value is at the bottom of the display, the penultimate
measured value is above it, and so on.
Continuous measurement
In continuous measurement mode, the measuring tool can be moved relative to the tar-
get, during which the measured value will be updated approx. every half a second. You
Bosch Power Tools
English | 27
1 609 92A 5DX | (27.01.2020)