Function of the main
valve:
Circuit function C
The pilot valve (circuit
function D) is installed in
a way that the manual
override is on the same
P
side as port P on the
body.
R
Circuit function C Circuit function D
The circuit function of the main valve is indicated on its type
label (see "Fig. 2").
Fig. 1:
Arrangement of the pilot valve
Function of the main
valve:
Circuit function D
The pilot valve (circuit
function C) is installed
in a way that the manual
override is on the same
A/B
P
A/B
side as port A/B on the
body.
R
5.3 Type label (example)
Seat size
Circuit function
Type
6430 C 12,0 PB
G1/2
24V
Identification number
Manufacturer's code
Voltage, current type, power
Connection type, operating pressure
Fig. 2:
Type label of solenoid valve Type 6430
Seal material
Body material
MS
P N 1 - 1 6 bar
DC
8W
00351175
W17MG