Mounting and Connection Instructions IK3 Evaluation Unit BUS-2
10.

Start-up

On completion of installation and after switching on the operating voltage, the following must be
programmed in the corresponding functions of the control panel:
The type of switching device, alloction of detector groups, authorization granted, IDENT-KEY
blocking time, possible IDENT-KEY-door release time and door strike functions. For operating units
with I/O and numerical keypad, the number of digits of the keypad code, the keypad code itself and a
hold-up detector group for the hold-up code can also be defined.
The installation mode is then activated at the control panel so that the addresses of the IK3 operating
units can be allocated.
Cover the screw opening with a
VdS seal.
VdS-approval:
When connecting an IK ope-
rating unit with a numerical
keypad, enter the VdS-approval
number in the column "with
tangible IM" and "with intangible
IM" (see example).
11.

Technical data

Rated operating voltage
Operating voltage range
Operating voltage U_BDT for one reader
Current consumption:
-
EU no-load current
-
GBS terminated with 12k1
-
Relay (Rel1 or REL2)
-
Blocking element actuation
via semi-conductor output
-
Buzzer
-
Outputs - IK2 operating unit
(Buzzer / Disarmed / alarm)
-
EU, plus all inputs terminated
plus 1 IK3 reader
Detector group inputs:
-
Release contact
-
Glass breakage sensor
-
Bolt switching contact
-
Cover contact - external reader
-
Door strike armature contact
-
Presence control
Contact rating of relays
Interface to readers
Protection category as per EN 60529
Environmental class as per VdS
Operating temperature range
Housing dimensions (W x H x D)
Colour
4.
Armimg/Disarming
Switching device (SD)
Y
With tangible ID
Profiled cylinder for SD
Y
With in
tangible ID
With time control
1)
Identification characteristic
12 V DC
9 V to 15 V DC
12 V DC,
output
short circuit-proof,
current-limited at 200 mA max.
< 15 mA (maximum value)
+ 1 mA
+ 17 mA
+ 1 mA
+ 3 mA
+ 3 mA per output
Type 25 mA
3.3 V DC DG, monitored at 12k1±40%
12
V DC DG, monitored at 12k1±30%
12 V DC DG, active LOW
3.3 V DC DG, monitored at 12k1±40%
3.3 V DC DG, monitored at 12k1±40%
12 V DC DG, active LOW
max. 2 A, 30 V AC/DC, 30 VA
RS-485
IP30
II
-5 °C to +55 °C
118 x 118 x 31 mm
traffic white (similar to RAL 9016)
Quantity Approval no.
1
1)
G
M
1
G
G
G
65
104030
104030