will now light and go out again as the alarm relay opens and
closes, making possible walk testing.
Notes
Enabling the walk test will not clear alarm memory. After
disarming the system after an alarm, you may switch to
walk test. When you switch back out of walk test, the
indication of memorized alarms will re-appear. Only when
"CV" is reapplied to terminal 9 (for example, system is re-
armed) will LEDs and memory be cleared.
To enable the walk test LED without a remote "CV" input,
connect a link between terminal 2 and 10.
Window mask
In the presence of objects close to (within 1.5 m) and directly
under the detector, fit the mask to the inside of the window as
shown in Figure 6.
This disables the part of the curtains looking at the object,
whose closeness might otherwise destabilize the detector.

Specifications

Voltage
Peak to peak ripple
Current
Normal operation
Alarm
Mounting height
Target speed range
Alarm output
Form A, voltage free
Alarm time
Tamper output
Max. detection range
Number of zones
Dimensions
Weight
Temperature
Relative humidity
Housing protection (with
sealed cable entry)

Regulatory information

Manufacturer
PLACED ON THE MARKET BY:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092,
USA
AUTHORIZED EU REPRESENTATIVE:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
P/N 143104999-5 • REV B • ISS 01MAR19
EV455P
EV456P
8 to 15 V
(12 V nom.)
2 V max. (at 12 V )
9 mA
13 mA
14 mA max.
16 mA max.
1.8 to 5.0 m
0.2 to 4.0 m/s
100 mA at 28 V,
100 mA at 28 V,
Form C, voltage free
relay
relay
2.5 s min.
100 mA at 28 V
25 m
1
103 x 71 x 51 mm
120 g
−18 to +55°C
93% max.
IP30 IK02
Product warnings
THESE PRODUCTS ARE INTENDED FOR
SALE TO AND INSTALLATION BY QUALIFIED
and disclaimers
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY "AUTHORIZED
DEALER" OR "AUTHORIZED RESELLER", IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/
Certification
European Union
UTC Fire & Security hereby declares that this
directives
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU and/or 2014/35/EU. For more
information see www.utcfireandsecurity.com or
www.interlogix.com.
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.utcfssecurityproducts.eu/recycle/

Contact information

www.utcfireandsecurity.com or www.interlogix.com
DE: Installationsanleitung
Einführung
Die Serie EV450P besteht aus PIR-Bewegungsmeldern.
Letztere verfügen über einen patentierten Spiegel sowie Pyro-
und Signalverarbeitungstechnologie.
Montageanleitungen
Siehe Abb. 1.
1.
Nehmen Sie die Abdeckplatte (Punkt 1) wie dargestellt ab.
Öffnen Sie den Melder (Punkt 2) und nehmen Sie das
2.
Elektronik-Modul (Punkt 3) heraus.
Achten Sie dabei darauf, daß Sie den pyroelektrischen
3.
Sensor (Punkt 4) nicht berühren.
4.
Brechen Sie je nach Erfordernis einen oder beide
Kabeleingänge (Punkt 5) heraus.
Verwenden Sie entweder die Befestigungsöffnungen für
5.
eine Eckenmontage (Punkt 6) oder auf einer Wand
(Punkt 7).
Verwenden Sie die Gehäuserückseite als Schablone für
6.
das Markieren der Befestigungslöcher auf der Wand.