LIVARNO LUX LLES B2
 Before installation, familiarise yourself with the individual parts of the energy-saving outdoor spotlight
as well as the text and illustrations of these operating instructions and comply with them.
 Make sure that the cable to which the energy-saving outdoor spotlight is to be connected is not live.
To ensure that this is the case, remove the appropriate circuit fuse from your fuse box or switch the
fuse to the "0" position.
 Make sure that the cable is not live using a voltage tester!

Installation

 Detach the wall bracket (6) from the energy-saving outdoor spotlight by removing the 2 screws (2)
with a Phillips screwdriver. Note that the wall bracket (6) is attached on both sides with a screw (2), a
spring washer and a flat washer. Keep these parts safe until you are ready to assemble them.
 Use the wall bracket (6) as a template to mark the two holes.
 Then drill the two holes and attach the wall bracket (6) using the supplied wall plugs and screws or,
depending on the installation location, using other suitable plugs and screws.
 Open the cable junction box (3) by loosening the four screws using a Phillips screwdriver and
removing the cover.
 Loosen the 2 screws on the strain relief within the cable junction box (3) with a Phillips screwdriver
only to the extent that the power cable (11) can be subsequently fed through it.
 Loosen the screw connection (5) of the cable bushing (4), but do not completely unscrew it.
 Remove approx. 5 to 8cm of the sheath of the power cable (11).
 First, route the power cable (11) through the screw connection (5) and the cable bushing (4), and
then through the strain relief in the cable junction box (3). When routing the power cable (11)
through the cable bushing (4), an internal rubber seal must be penetrated. A slight resistance may
thus be felt.
 Fix the power cable (11) by tightening the 2 screws on the strain relief within the cable junction box
(3). The end of the cable sheath must be in the strain relief for this purpose. Do not clamp the
individual wires!
 Then tighten the previously loosened screw connection (5) of the cable bushing (4) in a clockwise
direction. This ensures the sealing of the power cable (11).
 Connect the stripped wire ends of the power cable (11) using the screw terminal (12). Make sure that
the individual wires of the power cable (11) are connected correctly. Also pay attention in this context
to the illustration [B] on the inside cover.
Wire
Black or brown
Blue
Yellow/green
8 - English
Symbol
Designation
L
Phase
N
Neutral
Earth conductor