en
16 | VLE 2130 E | Installation
4.3
Electrical connection
!
Protective conductor checks are to be performed
following initial installation, repair work, installation
modifications and as specified by VDE 0100.
i
The circuit diagram can be found in Appendix A.
Main-Power
Motor 1
Fig. 3:
Steuerplatine
|
1 689 978 551
2017-11-17
4.3.1
¶
Power cord connection
Wire designation
Power cord
L1
L2
L3
N
PE
4.3.2
1. Connect the secondary column motor.
Wire designation
X 18
Secondary column motor
Wire 1
Wire 2
Wire 3
Motor 2
2. Connect the secondary column thermoswitch.
!
Always ensure correct PE connection.
Wire designation
Secondary column motor
Wire 4
Wire 5
PE
3. Connect the secondary column potentiometer.
!
Incorrect connection will destroy the printed circuit
board.
Wire designation
Secondary column motor
Wire 6
Wire 7
Wire 8
4.3.3
!
Check the main column first, then the secondary
column.
1. Briefly turn the rotary reversing switch to the left
(lower).
Main column support arms down, rotary field ok,
Main column support arms up, rotary field not
2. Briefly turn the rotary reversing switch to the left
(lower).
Secondary column support arms down, rotary
Main column support arms up, rotary field not
"
Test over.
Connecting power cord
Designation
Main-Power
X3
X4
X2
X6
X7
Secondary column connection
Designation
Motor 2
U
V
W
Designation
X 18
Thermo
Thermo
PE
Designation
X11 - SC potentiometer
GN (green)
WS (white)
BN (brown)
Checking rotary fields
continue with step 2.
ok, interchange wire L1 and L2 at motor 1.
field ok.
ok, interchange wire 1 and wire 2 at motor 2.
Robert Bosch GmbH