Maintenance
CAUTION
!
Risk of damaging the material!
Do not use any solvents (e.g. acetone, alcohol) or cleaning
agents containing abrasive particles for cleaning and
disinfecting. Only apply the described procedures and use
the cleaning and disinfecting agents given. Other agents,
dosages and exposure times may damage the product.
Do not use a cloth to clean or dry the inside of facepieces with
visors that are marked "PCaf", as the coating can be
damaged as a result. After drying, these facepieces should be
aired unpacked for at least one day under standard climatic
conditions according to DIN EN ISO 291, so that the coating
can regenerate and the optimum working life is achieved.
For information about suitable cleaning and disinfecting
agents and their specifications refer to document 9100081 on
www.draeger.com/IFU.
4.2.1
Cleaning and disinfecting procedure
1. Remove any accessories from the facepiece and clean them
separately.
2. Prepare a cleaning solution consisting of water and a cleaning
agent.
3. Clean all parts using a soft cloth with cleaning solution.
4. Thoroughly rinse all parts under running water.
5. Prepare a disinfecting solution consisting of water and a
disinfecting agent.
6. Place all parts that need to be disinfected into the disinfectant bath.
7. Thoroughly rinse all parts under running water.Dry all parts in the
air or in a drying cabinet (max. temperature: 140 °F/60 °C). Do not
expose to direct sunlight. Do not shake the facepiece in order to
remove water.
8. Mount the accessories if necessary.
176
4.2.2
1. Remove any accessories from the facepiece and clean them
2. Prepare a solution containing water and a combined cleaning and
3. Immerse the facepiece in the solution. Make sure that all parts are
4. Thoroughly rinse all parts under running water.
5. Dry all parts in the air or in a drying cabinet (max. temperature:
6. Mount the accessories if necessary.
(Use Instructions for NIOSH-approved full facepieces)
Alternative cleaning and disinfecting procedure
separately.
disinfecting agent.
wetted.
140 °F/60 °C). Do not expose to direct sunlight. Do not shake the
facepiece in order to remove water.