In the event of a fault developing, contact your nearest
Service Centre-see local telephone directory.
www.dometic.com
9. Putting into operation
Technical data:
Model
RH 456LD
RH 456LDE (Built-in)
Type
MB20-60
Gross volume
56 litres
Cooled volume
40 litres
Uncooled volume
16 litres
Mains operation
220-240V (AC)
Input
65W
Energy consumption
0.830 kWh/24h
Refrigerant
159g H
* The energy consumption is measured at 12°C at 25°C environment
temperature (cellar).
9.1. Connecting to electrical mains
The appliance may only be operated from
nominal voltage mains as shown on the data
plate. The appliance mains plug may be connected to
a mains socket earthed in accordance with regulations.
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
The manufacturer declines any liability should
these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance
rating plate.
Only for UK:
The appliance is supplied with a 3 Amp plug fitted. In
the event of having to change the fuse in the plug
supplied, a 3 Amp ASTA approved (BS 1362) fuse
must be used. Should the plug need to be replaced
for any reason, the wires in the mains lead are
coloured in accordance with the following code:
Green and Yellow: Earth
Blue:
Neutral
Brown:
Live
O+86g NH
2
3
The wire coloured green and yellow must be
connected to the terminal marked with the letter "E"
or by the earth symbol
yellow.
The wire coloured blue must be connected to the
terminal "N" or coloured black.
The wire coloured brown must be connected to the
terminal marked "L" or coloured red.
Upon completion there must be no cut, or stray
strands of wire present and the cord clamp must be
secure over the outer sheath.
10. Environmental protection
information
Ammonia
(natural
compound) is used as a refrigerating agent in the
refrigeration unit.
The ozone-friendly cyclopentane is activated as a
motive agent for the PU foam insulation.
Sodium chromate is used for corrosion protection
(less than 2 weight % of the coolant).
11. Recycling
After unpacking the appliance, the packing
materials should be delivered to a local collection
site. At the end of its useful lifetime, the appliance
should be delivered to a specialized collection and
reprocessing firm, which reclaims the usable
materials. The rest is properly destroyed.
Appliances bearing this symbol must be
deposited at the designated local
reception point for the disposal of
electrical and electronic equipment.
It is not permitted that this product be
disposed of by way of the normal
household refuse collection system.
Dometic refrigerators bear this symbol on the
specifications plate (data plate) to be found in the
interior of the unit.
This appliance complies with the following EEC
directives:
LVD-Directive
73/23/EEC with amendment
90/683/EEC
EMC-Directive
89/336/EEC
RoHS - Directive
2002/95/EC
or coloured green and
hydrogen
and
nitrogen
GB
9