How to proceed:
J
Remove the screws for fastening the filter basket and remove the filter basket.
Clean all parts.
– Use a soft brush.
– Rinse parts in clean water.
Reassemble the unit in the reverse order.
Replacing the impeller unit
N O T E
The impeller unit contains strong magnets that attract magnetic particles (e.g. iron filings).
• All particles must be removed from the impeller unit before reassembly. Any remaining particles can cause
irreparable damage to the impeller unit and motor block.
Prerequisite:
• The pipes/hoses at the inlet and outlet are removed.
How to proceed:
K
Remove the screws for fastening the filter basket and remove the filter basket.
Remove the screws for fastening the stand and remove the stand.
Remove the four screws and take off the pump casing.
Pull out the impeller unit and replace if necessary.
– Use a wide-blade screwdriver to carefully lever out the impeller unit if necessary.
Reassemble the unit in the reverse order.
The impeller unit is guided in the motor block by a bearing. This bearing is a wear part and should be changed
at the same time as the impeller unit.
• Changing the bearing requires specialist knowledge and tools. Have the bearing changed by your OASE
specialist dealer or send the pump to OASE.
Wear parts
• Impeller unit
• Bearing in the motor block
Storage/overwintering
The unit is frost resistant to minus 20 °C. Should you store the unit outside of the pond, clean it thoroughly with a soft
brush and water, check it for damage, then store immersed in water or filled with water. Do not immerse the power plug
in water!
Repair
Repair is not possible in the following cases. The pump has to be replaced.
• If there is no replacement part approved by OASE for a defective component.
• If an electric cable permanently connected to the pump becomes damaged or is shortened.
If repair work by OASE becomes necessary, always send both the pump and the switching power pack to OASE or
give them to your specialist retailer.