Limit 97
OPERATION MANUAL
English
Overview
LIMIT 97 series professional non-contact infrared thermometer can determine surface temperature
through measuring infrared energy radiated by the target surface.
Warning:
To avoid eyes injury, do not look directly in to the laser beam.
Specifications Limit 97
Measurement range :
Accuracy :
D:S ratio :
Emissivity :
Response time :
Spectral response :
Display resolution :
Repeatability :
Laser quantity :
Laser type :
Laser wavelength :
Laser power :
Battery type :
Battery life :
Product size :
Weight:
Operating temperature:
Operating humidity:
Operating altitude:
Storage altitude:
Protection level:
Drop test:
Features
•
3 m drop tested
•
IP65, dust and water protection
•
Ergonomic design
•
MAX/AVG/DIF/MIN function
•
Large screen with backlight
•
Alarm function
•
Dual Laser beams
Display symbol
Trigger free measuring activated
Laser ON
High and Low limit alarm
Low battery
Temperature measuring
Measurement data hold
Unit
Main display value
Selected function
Emissivity
Secondary display value
Operations:
1. Power On and off
1.1 Gently pull the trigger to power on thermometer, LCD screen and backlight will turn on.
1.2 The thermometer will power off automatically if there are no operation in 8 s.
-35 °C~650 °C (-31 °F~1202 °F)
0 °C - 100 °C: ±1.8 °C / 101 °C - 650 °C: ±1.8%
< 0 °C: ± (1.8 °C+0.1 °C/°C)
12:1
0.1-1.0 adjustable
250 ms (95% of reading)
8 um~14 um
0.1 °C (0.1 °F)
± 1.0 °C or 0.8% of reading, whichever greater.
Dual laser
Class II
630 ~670 nm
<1 mW
9 V battery (6F22)
10 h (Work continuously with backlight on)
189 mm x 118 mm x 55 mm
292 g
0 °C~50 °C (32 °F~104 °F)
<90% RH (non-condensing)
2000 m
12000 m
IP65
3 m
1
English