REPLACING THE CENTRE BRUSH

Caution: this operation must be carried out with the machine
off and the key removed.
This machine features a system for automatically adjusting the
pressure exerted and compensating for wear.
The need to replace the central brush is highlighted on the
display by the wording "BRUSH WORN OUT"
To replace the centre brush, proceed as follows:
Open up the door on the left hand side of the machine by
loosening the knob, as shown in the figure.
Unscrew and remove the knobs that fix the brush housing
cover
Remove the cover of the brush compartment.
English (Translation of original instructions)
Remove the worn brush.
Remove the adapter of the brush stem and fit it onto the new
brush. Maintain the same inclination of the bristles. (See the
next figure).
Refit the adapter and mount the new brush. Make sure the
adapter is inserted into the hub.