Maintenance
4.2

Cleaning and disinfecting

The facepiece must be cleaned after every use so that it is clean
before it is used by a different individual or, if individually assigned, as
often as necessary to keep in a sanitary condition. Facepieces that are
issued to more than one user must be cleaned before being worn by
different individuals.
The facepiece must be disinfected after every use to keep it in a
sanitary condition. It is fully in the user's responsibility to make sure
that the facepiece is totally free of contaminants after this treatment.
Never use a facepiece again, that has not been properly disinfected.
In case of doubts dispose of the facepiece in accordance with the local
regulations and use a new one.
WARNING
!
The facepiece body must be cleaned thoroughly so that no
residues from skin care products remain on it.
Otherwise the elasticity in the sealing area can be lost and the
facepiece will no longer fit correctly.
If this warning is not heeded, poisoning or death can result.
CAUTION
!
Risk of damaging the material!
Do not use any solvents (e.g. acetone, alcohol) or cleaning
agents containing abrasive particles for cleaning and
disinfecting. Only apply the described procedures and use
the cleaning and disinfecting agents given. Other agents,
dosages and exposure times may damage the product.
For information about suitable cleaning and disinfecting
agents and their specifications refer to document 9100081 on
www.draeger.com/IFU.
80
4.2.1
1. Remove any accessories from the facepiece and clean them
2. Prepare a cleaning solution consisting of water and a cleaning
3. Clean all parts using a soft cloth with cleaning solution.
4. Thoroughly rinse all parts under running water.
5. Prepare a disinfecting solution consisting of water and a disinfect-
6. Thoroughly rinse all parts under running water.
7. Dry all parts in the air or in a drying cabinet (max. temperature:
8. Mount the accessories if necessary.
4.2.2
1. Remove any accessories from the facepiece and clean them
2. Prepare a solution containing water and a combined cleaning and
3. Immerse the facepiece in the solution. Make sure that all parts are
4. Thoroughly rinse all parts under running water.
5. Dry all parts in the air or in a drying cabinet (max. temperature:
6. Mount the accessories if necessary.
(Use Instructions for NIOSH-approved full facepieces)
Cleaning and disinfecting procedure
separately.
agent.
ing agent. Place all parts that need to be disinfected into the disin-
fectant bath.
140 °F/60 °C). Do not expose to direct sunlight. Do not shake the
facepiece in order to remove water.
Alternative cleaning and disinfecting procedure
separately.
disinfecting agent).
wetted.
140 °F/60 °C). Do not expose to direct sunlight. Do not shake the
facepiece in order to remove water.