OPERATING PRINCIPLE
The fuel (pellets) is taken from the hopper (A) and, using a
screw (B) operated by a gear motor (C), is sent to the crucible
(D).
The pellets are lit by hot air produced by an electrical element
(E) sucked into the crucible through a smoke extractor fan (F).
The smoke produced by combustion is extracted from the
combustion chamber by the same fan (F) and expelled from the
vent (G) which can be connected to the back, the left side or
the top of the stove (see page 207).
The combustion chamber, with base and ceiling in Vermiculite,
closed at the front by a door in ceramic glass (special "cold-
hand" handle to open the door).
The water in the boiler is heated and sent by the built-in pump
(H) to the heating system.
The stove has a closed expansion tank (I) and a built-in pres-
sure safety valve (L).
The quantity of fuel, the extraction of the smoke and the input
of air for combustion are regulated by a motherboard equipped
with software, to obtain a high combustion yield and low emis-
sions.
The stove has a serial socket for optional wire connection (code
640560) to remote controlled ignition devices (chrono-thermo-
stats etc.).
The ceramic outer casing is available in three colour variants:
cream, burgundy and grey.
D
H
F
A
B
E
C
G
L
I
SAFETY INFORMATION
IDROPOINT MUST NEVER OPERATE WITHOUT WATER
IN THE SYSTEM.
SWITCHING ON WHEN "DRY" CAN DAMAGE THE
STOVE.
IDROPOINT MUST OPERATE WITH A PRESSURE OF
ABOUT 1.5 BARS.
• The only risks deriving from the use of the stove are linked
to not respecting the installation rules, direct contact with live
electrical parts (internal parts), contact with flames or hot parts
(glass, pipes, hot air output) or to the introduction of foreign
substances.
• If any component does not function correctly, the stove has
safety devices which guarantee that it will switch off; in such
cases, allow the stove to switch itself off without intervening.
• To function correctly, the stove must be installed according
to the indications given on this sheet and the door must not be
opened during operation: combustion is managed automati-
cally, no action is necessary.
• For fuel, use only wood pellets with a diameter of 6 mm.
• Under no circumstances may foreign substances be placed in
the combustion chamber or the pellet hopper.
• The flue (the duct connecting the smoke output vent of the
stove to the chimney) must not be cleaned with flammable
products.
• Do not clean when hot.
• The parts of the combustion chamber and the pellet hopper
must be vacuumed only when COLD.
• The glass can be cleaned when it is COLD with a special
product applied with a cloth.
• Make sure the stove is installed and switched on for the first
time by an Edilkamin authorised TAC (Technical Assistance
Centre) according to the indications given on this sheet; other-
wise the guarantee will not be valid.
• During operation, the discharge pipes become very hot (do
not touch them without the special glove).
• Do not place heat-sensitive objects next to the stove.
• NEVER use flammable liquids to light the stove or to revive
hot embers.
• Do not block ventilation into the room where the stove is
installed, and do not block the air intake of the stove itself.
• Do not allow the stove to get wet, and do not place wet hands
anywhere near the electrical parts.
• Do not insert reductions into the smoke discharge pipes.
• The stove must be installed in a room with an adequate
fire-prevention system, and it must also be provided with all
systems (input and discharge) required by the stove for safe
operation .
• Make sure that the return water temperature is at least 45°C-
50°C.
• The temperature of the room where the stove is installed must
not fall below 0°C.
• If necessary, add antifreeze liquid to the water of the system.
• If the stove does not light, do NOT repeat ignition before
having emptied the crucible.
• ATTENTION:
PELLETS REMOVED FROM THE CRUCIBLE MUST
NOT BE PLACED BACK INTO THE HOPPER.
- 201
-