NEW MODEL 2011
The instruction manual is downloadable from the site www.vimar.com
DESCRIPTION
Monitor for video door entry system with 4 and 8 digit coding and decoding. Provided
with fixing bracket with terminal block, 3 push-buttons (lock release and 2 adidtional
functions), 3 level call volume adjustment and exclusion of call signalled by red led. The
green LED is used for an additional signaalling (when properly connected).
This monitor is used in conjuction with power supply type 6948.
204 mm
Monitor technical specifications
- Wall-mounted monitor in ABS
- Backing plate and plugs for wall-mounted fixture or 3-module box.
- TFT LCD 3,5" for 6344 and 6354.
- Electronic circuit on interchangeable cards.
- Standard video signal CCIR 625 lines 50 squares for 6344 (b/w) and PAL for 6354
(color).
- Video pass band 4 MHz
- Operating temperature from 0° to +40° C.
- Electronic ringtone.
- Input for door calls with different ringtone from panel calls.
- Output for additional ringtone.
PROGRAMMING AND OPERATION
To program the monitor number press (by inserting a small screwdriver through the
hole Fig. 1, detail A) the push-button
then press and keep pressed the push-button. If the operation has been carried out
correctly, the set enter the programming mode by lighting the diode LED (Fig. 1, detail
B) also visible through the hole under the monitor. Now the push-button
released. If the diode does not light up repeat the operation. Lifting the monitor handset
it is possible to communicate with the secondary entrance panel in order to send the
code related to the monitor to be programmed. When the code coming from the en-
trance panel arrives to the monitor, this stores it and keeps it in memory until the next
programming, even during a mains failure. The monitor will switch the led off confirming
the programming. During the programming phase the lock release command is not
active. In case of installations with stairs with more than one entry, for the only program-
ming phase , it is necessary to remove the connector related to the monitor riser of
entrance panels, leaving only one in function. The programming operation may be re-
peated several times by using numbers included between 00000001 and 99999999.
PROCEDURE FOR "TOUCH KEY" PROGRAMMING
To program a "touch key" in the monitor memory follow the underwritten procedure:
1) Call the monitor from a digital keypad entrance panel
2) Re-dial the number and press the intercommunicating call push-button from the
entrance panel
3) Select the position in the memory, by using the "FRECCIA SU" (arrow up) and
"FRECCIA GIU'" (arrow down), where you want to memorize the key and press C.
4) Lean the key "TOUCH" in the proper entrance panel slot; you will hear an acoustic
signal on the monitor handset.
5) From now you will have 5 seconds to memorize the key by pressing the monitor
"lock" push-button; once the programming has been carried out you will hear three
beeps and the monitor will switch off. If the programming time expires before you
press the lock push-button, the interphone will switch off without programming the
key and all the procedure must be repeated from the beginning.
ADJUSTMENT OF CALL/UNATTENDED CALL FUNCTION
The 4 position selector (Fig. 1, detail C) allows the loudspeaker volume to be ajusted
and, if set to the last left position, it excludes the audio by lighting the red LED. If a call is
made during this period, the monitor does not sound and it is not activated, but it signals
the call making the led flash and a call be routed to the switchboard. The number of
flashings (max 4) indicates the number of incoming calls. Setting the selector again,
the normal operation is re-establised and the number of incoming calls stored in the
memory on this mode is cancelled.
EN
74 mm
present on the lower side of monitor and
can be
*
.
VIDEO SIGNAL CONNECTION
If the video signal is connected by a coaxial cable, the deviator (Fig. 2, detail A) (placed
on the monitor rear side) must be set to the left hand position for the coxial cable ver-
sion, or in the right hand position for version withoutcoaxial cable.
N.B. The jumper present on the monitor rear side allows the VIDEOMOVING func-
tion to be carried out on preset entrance panels or Function 2; on the contrary
with cut jumper it allows the selfactivation function to be carried out (Fig. 2,
detail B), see entrance panel programming.
TERMINAL BLOCK
1) Digital call line
2) Secondary entrance panel audio line
3) Audio line
4) Negative line
5) + 13,5V DC line
6) Inserted monitor signalling (for additional chimes or other services)
7) Monitor negative line
8) Monitor positive line
9) Line for outside door call.
10) Supply voltage for video floor distributor
11) F2 - connection for auxiliary functions, to be connected if indicated on the diagram.
12) F1 - Connection for auxiliary functions, to be connected if indicated on the diagram.
13) Supply voltage for green LED indicator
Lower side of monitor
Fig. 1
Rear monitor
COLL.
MONITOR
PAL / NTSC
6354
COLORE - COLOR
6324/C
6344
B/N
- B/W
6324
DC 18V INT 6W 335mA
MATRICOLA
REG.
N. MVAP
INSTALLATION RULES.
Installation should be carried out observing current installation regulations for electrical sys-
tems in the Country where the products are installed.
CONFORMITY.
EMC directive
Standards EN 60065, EN 61000-6-1 and EN 61000-6-3.
INFORMATION FOR USERS UNDER DIRECTIVE 2012/19/UE (WEEE)
In order to avoid damage to the environment and human health as well as any ad-
ministrative sanctions, any appliance marked with this symbol must be disposed of
separately from municipal waste, that is it must be reconsigned to the dealer upon
purchase of a new one. Appliances marked with the crossed out wheelie bin symbol must
be collected in accordance with the instructions issued by the local authorities responsible
for waste disposal.
Fig. 2
CON PONTICELLO INSERITO = FUNZIONE F2
PONTICELLO TAGLIATO = FUNZIONE AUTOACCENSIONE
WITH JUMPER INSERTED = FUNCTION F2
WITH JUMPER CUT = SELFACTIVATION FUNCTION
M a d e
in Italy
3