INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
GB
FOR COOKER HOOD MODEL VCCH6506.1 W, 230-240 Vac - 50 Hz
Exhausting cooker hood. The equipment is constructed in accordance with European Standards and with the requirements included in the
following Directives: 2006/95EC ( Low Voltage Directive), 2004/108 (Electromagnetic Compatibility).
PRESENTATION
The unit (Picture 1) is composed of the following elements:
1) hood module
2) telescopic chimney (optional)
INSTALLATION
Read the instruction manual before installing and/or using the hood.
The unit must be fitted at a distance of at least 60 cm. from the cooking
hob. If the mounting instructions of the gas cooker indicate a wider
distance, respect it. The unit must not be mounted above cookers fitted
with top radiant plate.
Respect all the air discharge regulations.
The air must not be discharged in a pipe used to discharge exhaust fumes
produced by gas-fed equipments or fuel-fed equipments (this does not
apply to filtering hoods).
The room must be adequately ventilated when the hoods is used together
with other gas-fed or fuel-fed equipments. For an easy access, it is
advisable to move possible furniture under the installation area.
Installation of the hood onto the wall.
The hood is equipped with all the necessary fastenings for its installation,
which are suitable for most surfaces. Verify that the installation surface
is strong.
Installation must be carried out by qualified installers according to
present regulations.
www.velgehome.com
1)Draw and drill the wall as in Picture 2
2)Fix on the wall the screw anchors with its support (A).
3)Fix with screw anchors (C) the support of the telescopic chimney (B).
4)Put the screw anchors on the holes (D)
5)Fix the hood to the screw anchors see point 2), two people are needed
for this operation.
6)Block the equipment with screws (E), to reach these fastenings open
the frontal panel.
7)Apply the pipe and/or the drain connection.
8)Fix the telescopic chimney on the vents on the upper part of the hood
and fix it to the support with screws (F).
ELECTRICAL CONNECTIONS
This equipment must be connected to a grounding plant. Two types of
electrical connection can be used:
1)Using a standard plug to be connected to the power cable and inserted
in a mains socket which must be accessible (so that the plug can be
disconnected when servicing is carried out). Make sure that the plug is
accessible also after the complete installation of the equipment.
2)By means of a fixed mains connection, fitting a bipolar switch, which
ensures the disconnection, with an opening distance of the contacts
allowing a complete disconnection on the conditions of the overvoltage
III category, according to installation regulations. The ground connection
(yellow-green wire) must not be interrupted.