14 | English
(15) Button MTR2 for compound mitre (GAM 220 MF)
(16) Leg extension (GAM 220 MF)
(17) Protective bag
Display Elements
(a) Indicator H for saved value Hold
(b) Battery indicator
(c) Measured value
(d) Bevel angle indicator BVL (GAM 220 MF)
(e) Mitre angle indicator MTR (GAM 220 MF)
(f) Corner angle indicator CNR (GAM 220 MF)
(g) Spring angle indicator SPR (GAM 220 MF)
Technical Data
Digital angle measuring
device
Article number
Hold function
Display illumination
"Simple mitre" operating
mode
"Compound mitre" operating
mode
Measuring range
Measuring accuracy of angles
Smallest display unit
Operating temperature
Storage temperature
Max. altitude
Relative air humidity max.
Pollution degree according to
IEC 61010-1
Batteries
Rechargeable batteries
Operating lifetime (alkali-
manganese batteries) ap-
prox.
Automatic switch-off after
approx.
Leg length
Weight according to EPTA-
Procedure 01:2014
Dimensions (length × width ×
height)
IP 54 (dust and splash-proof)
A) Only non-conductive deposits occur, whereby occasional temporary conductivity
caused by condensation is expected.
The serial number (10) on the type plate is used to clearly identify your measuring tool.
Assembly
Inserting/Replacing Batteries (see figure A)
It is recommended that you use alkaline manganese batteries to operate the
measuring tool.
To open the battery compartment cover (5), press the locking mechan-
ism (6) and fold the battery compartment cover up. Insert the batteries/re-
chargeable batteries.
When doing so, ensure that the polarity is correct and corresponds to the
diagram on the battery compartment cover.
Battery Indicator
The battery indicator (b) always indicates the current battery status:
Indicator Capacity
90–100 %
60–90 %
30–60 %
10–30 %
0–10 %
The empty battery indicator flashes. You can measure for ap-
proximately another 15–20 min from when the flashing begins
until the tool shuts down.
Always replace all the batteries at the same time. Only use batteries from the
same manufacturer and which have the same capacity.
1 609 92A 58K | (18.11.2019)
GAM 220
3 601 K76 5..
0–220°
±0.1°
0.1°
–10 °C to +50 °C
–20 °C to +70 °C
2000 m
90%
A)
2
4 × 1.5 V LR6 (AA)
4 × 1.2 V HR6 (AA)
80 h
30 min
400 mm
1.3 kg
447 × 52 × 60 mm
GAM 220 MF
3 601 K76 6..
0–220°
±0.1°
0.1°
–10 °C to +50 °C
–20 °C to +70 °C
2000 m
90%
A)
2
4 × 1.5 V LR6 (AA)
4 × 1.2 V HR6 (AA)
80 h
30 min
400 mm
1.2 kg
447 × 52 × 60 mm
Bosch Power Tools