Tips for maintaining maximum
battery life
Charge the battery cartridge before completely
1.
discharged. Always stop tool operation and
charge the battery cartridge when you notice
less tool power.
Never recharge a fully charged battery car-
2.
tridge. Overcharging shortens the battery
service life.
Charge the battery cartridge with room tem-
3.
perature at 10 °C - 40 °C (50 °F - 104 °F). Let
a hot battery cartridge cool down before
charging it.
4.
Charge the battery cartridge if you do not use
it for a long period (more than six months).
FUNCTIONAL
DESCRIPTION
CAUTION:
•
Always be sure that the tool is switched off and
the battery cartridge is removed before adjust-
ing or checking function on the tool.
•
Take care not to trap finger(s) between cleaner
and battery as shown in diagram when loading
battery. Trapping finger(s) may cause injury.
► Fig.1
Installing or removing battery
cartridge
► Fig.2: 1. Red indicator 2. Button 3. Battery cartridge
CAUTION:
•
Always switch off the tool before installing or
removing of the battery cartridge.
•
Hold the tool and the battery cartridge firmly
when installing or removing battery car-
tridge. Failure to hold the tool and the battery
cartridge firmly may cause them to slip off your
hands and result in damage to the tool and
battery cartridge and a personal injury.
To remove the battery cartridge, slide it from the tool
while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on the
battery cartridge with the groove in the housing and slip
it into place. Insert it all the way until it locks in place
with a little click. If you can see the red indicator on the
upper side of the button, it is not locked completely.
CAUTION:
•
Always install the battery cartridge fully until the
red indicator cannot be seen. If not, it may acci-
dentally fall out of the tool, causing injury to you
or someone around you.
•
Do not install the battery cartridge forcibly. If the
cartridge does not slide in easily, it is not being
inserted correctly.
Battery protection system
The cleaner is equipped with the protection system, which
automatically cuts off the output power for its long service life.
The cleaner stops during operation when the cleaner
and/or battery are placed under the following situation.
This is caused by the activation of protection system
and does not show the cleaner trouble.
•
When the cleaner is overloaded:
At this time, release the switch trigger and
remove causes of overload and then pull the
switch trigger again to restart.
•
When the remaining battery capacity gets low:
Recharge the battery cartridge.
Switch action
► Fig.3: 1. OFF button 2. HIGH/LOW button
3. Battery power lamp
To start the cleaner, simply press the "HIGH/LOW" button. To
switch off, press the "OFF" button. To change the cleaner speed,
press the "HIGH/LOW" button. The first press on this button is for
high speed and the second press for low speed and then each
press on this button repeats the high/low speed cycle alternatively.
Lighting the lamp
For Model DCL182F only
CAUTION:
•
Never look into the light directly. Direct light
causes damage to your eyes.
► Fig.4: 1. OFF button 2. HIGH/LOW button
3. Battery power lamp 4. Lamp
To turn on the lamp, simply press the "HIGH/LOW"
button. To turn off the lamp, press the "OFF" button.
Indicating the remaining battery capacity
Only for battery cartridges with the indicator
► Fig.5: 1. Indicator lamps 2. Check button
Press the check button on the battery cartridge to indicate the remain-
ing battery capacity. The indicator lamps light up for a few seconds.
Indicator lamps
Lighted
9 ENGLISH
Off
Blinking
malfunctioned.
Remaining
capacity
75% to 100%
50% to 75%
25% to 50%
0% to 25%
Charge the
battery.
The battery
may have