CLEANING AND MAINTENANCE

Attention! Before
performing any work on
the equipment, pull the
Service
§ Only qualified specialist personnel and original
replacement parts should be used for repairs.
This will ensure that your device remains safe.
Cleaning
§ Regularly clean the machine housing with a soft
cloth, preferably after each use. Keep the
ventilation slots free from dust and dirt. If the dirt
does not come off use a soft cloth
moistened with soapy water. Never use solvents
such as petrol, alcohol, ammonia water,
etc. These solvents may damage the plastic
parts.
Checking the oil-level
Check the oil-level prior to each use.
Fat level should not be less
3 mm, if the level is below, add oil.
To refill the oil, proceed as follows:
_
Remove the plug from the fillingpoint.
Use the spanner supplied.
_
Refill the oil.
_
Replace the plug and tighten it securely.
Checking and replacing the carbon brushes
The carbon brushes must be checked on a
regular basis.
_
Remove the carbon brush holders and clean
the carbon brushes.
_
In case of wear, replace both carbon brushes at
the same time.
_
Mount the carbon brush holders.
_
After mounting new carbon brushes, let
the machine run at no load for 15 minutes.
Use only the correct type of

TECHNICAL DATA

Mains voltage V
Mains frequency Hz
Power input W
Joules
-1
Speed (no load) min
-1
Impact number min
Chuck
xmm
Weight kg
power plug.
carbon brushes.
230
50
1700
60
19300
1900
HEX30x410
16
Page 18 of 36
Noise emission values measured according to
relevant standard.
Acoustic pressure level
L
92.87 dB(A) K = 3 dB(A)
PA
Acoustic power level
L
105dB(A)
WA
The sound power pressure may
exceed 85 dB(A), in this case
individual hearing protection
Weighted root mean square acceleration
according to relevant standard. :
18.575 m/s²
K = 1,5 m/s²
The declared vibration total value
has been measured in accordance with a
standard test method and may be used for
comparing one tool with another that the
declared vibration total value may also be
used in a preliminary assessment of
exposure.
A warning that the vibration
emission during actual use of the power tool
can differ from the declared total value
depending on the ways in which the tool is
used and of the need to identify safety
measures to protect the operator that are
based on an estimation of exposure in the
actual conditions of use (taking account of all
parts of the operating cycle such as the times
when the tool is switched off and when it is
running idle in addition to the trigger time).

SERVICE DEPARTMENT

_ Damaged switches must be replaced by our
after-sales service department.
_ If replacing the power cord is necessary, it
should be done by the manufacturer or his
agent to avoid a hazard.
After-sales Service and Application Service
Our after-sales service responds to your
questions concerning maintenance and repair of
your product as well as spare parts. Exploded
views and information on spare parts can also be
found
under:www.eco-repa.com
BRICK application service team will gladly
answer questions concerning our products and
their accessories : sav@eco-repa.com
K = 3 dB(A)
ATTENTION !
must be worn.

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für BRICK MP1700-642MC

Inhaltsverzeichnis