DANGER: Do not handle pressurized hoses. Escaping
oil under pressure can penetrate the skin, causing
serious injury. If oil is injected under the skin, see a
doctor immediately.
WARNING: Only use hydraulic cylinders in a coupled
system. Never use a cylinder with unconnected couplers. If
the cylinder becomes extremely overloaded, components
can fail catastrophically causing severe personal injury.
WARNING: BE SURE SETUP IS STABLE BEFORE
LIFTING LOAD. Cylinders should be placed on a fl at
surface that can support the load. Where applicable, use
a cylinder base for added stability. Do not weld or otherwise
modify the cylinder to attach a base or other support.
Avoid situations where loads are not directly centered
on the cylinder plunger. Off-center loads produce
considerable strain on cylinders and plungers. In
addition, the load may slip or fall, causing potentially dangerous
results.
Distribute the load evenly across the entire saddle
surface. Always use a saddle to protect the plunger.
IMPORTANT: Hydraulic equipment must only be serviced
by a qualifi ed hydraulic technician. For repair service,
contact the Authorized ENERPAC Service Center in your
area. To protect your warranty, use only ENERPAC oil.
WARNING: Immediately replace worn or damaged parts
by genuine ENERPAC parts. Standard grade parts will
break causing personal injury and property damage.
ENERPAC parts are designed to fi t properly and withstand high
loads.
WARNING: Keep hands clear of moving parts and
pressurized hoses.
WARNING:
adjusted relief valves, which must not be repaired or
adjusted except by an Authorized Enerpac Service
Center.
II 2 GD ck T4
ZA4 PERFORMANCE CHART
Motor
Output Flow Rate
Size
100 psi
5,000 psi
(hp)
4*
850
675
* Actual power consumption depends on the application. See Figure 1.
These pumps have internal factory
(in
/min)
3
5,000 psi
10,000 psi
110
80

3.0 SPECIFICATIONS

3.1 Performance Chart (see Performance Chart
below)
3.2 Flow Chart
Figure 1
800
700
600
500
400
300
200
100
0
0
1000
Flow (in

4.0 INSTALLATION

Install or position the pump to ensure that air fl ow around the
motor and pump is unobstructed. Keep the motor clean to
ensure maximum cooling during operation.
4.1 Reservoir Breather Cap (See Figure 2)
For shipping purposes, a shipping plug (A) is installed in the
breather port on the top of the reservoir. Before using replace the
shipping plug with the breather cap (B). NOTE: The breather port
(B) is separate from the oil fi ll port (C). Oil fi ll port (C) uses a SAE
#10 plug.
Dynamic
Air
Air Pressure
Consumption
Range
(s
(psi)
cfm)
60-100
20-100
2
Flow vs. Pressure
100 psi dynamic air pressure
@ 70 scfm air consumption
2000
3000
4000
5000
6000
3
/min)
A
Figure 2, ZA4 Breather Installation
Sound Level
@ 100 psi dynamic
(dBA)
94-97
7000
8000 9000 10,000
Pressure (psi)
B
C
Relief Valve
Adjustment Range
(psi)
1000-10,000