11.2 IMPIANTO ELETTRICO QUADRO PRINCIPALE
11.2 WIRING DIAGRAM MAIN BOARD
11.2 ELEKTRISCHEN ANLAGE - HAUPTSCHALTTAFEL
11.2 INSTALACIÓN ELECTRICA CUADRO PRINCIPAL
11.2 INSTALLATION ELECTRIQUE - TABLEAU PRINCIPAL
RAV232 NL - RAV234 NL - RAV236 NL
25
1
26
2
RIF.
NOMENCLATURA
MORSETTO
KS
CONTATTORE COMANDO MOTORE IN SALITA
TR
TRASFORMATORE 200VA Vp 0/230/400 Vs 0/18 0/24
KL
CONTATTORE DI LINEA
KD
CONTATTORE COMANDO MOTORE IN DISCESA
STM
TERMOSONDA MOTORE
SC
COMMUTATORE SELEZIONE COPPIE COLONNE
R4
RESISTENZA 1/4W 5,6K
R3
RESISTENZA 1/4W 10K
R2
RESISTENZA 1/4W 15K
R1
RESISTENZA 1/4W 39K
KSF
RELE' CONTROLLO SEQUENZA FASI
K4/5
RELE' DI EMERGENZA
K3
RELE' COMANDO DISCESA
K2
RELE' COMANDO SALITA
K1
RELE' COMANDO MOTORE
PS
PULSANTE DI SALITA
PRD
PONTE RADDRIZZATORE
PLC
CONTROLLORE LOGICO PROGRAMMABILE
PEM
PULSANTE DI EMERGENZA A FUNGO
PD
PULSANTE DI DISCESA
P1
PULSANTE GIALLO MOVIMENTO SINGOLO
M
MOTORE
L2
SPIA ROSSA EMRGENZA E BLOCCO
L1
SPIA BIANCA SEQUENZA FASI CORRETTA
IG
INVERTITORE GENERALE 1-0-2 ( 40A )
FU6
FUSIBILE PROTEZ. 24Vdc PLC 5x20 1A 250V RAPIDO
FU5
FUSIBILE PROTEZ. SECONDARIO TR(18V) 5x20 4A 250V RAP.
FU4
FUSIBILE PROTEZIONE SECONDARIO TR (24V) 5x20
4A 250V RAPIDO
FU3
FUSIBILI PROTEZIONE PRIMARIO TR 10.3x38 2A 500V gl
FU2
TERNA FUSIBILI PROTEZIONE LINEA MOTORE 10.3x38
16A 500V aM (VERS.230V) 10.3x38 10A 500V aM (VERS.400V)
FU1
TERNA FUSIBILI PROTEZIONE LINEA 14x51 50A 500V aM
(VERS.230V) 14x51 32A 500V aM (VERS.400V)
FCUB
FINECORSA USURA BUSTA
FCS
FINECORSA SALITA
FCP
INTERRUTTORE DI PROSSIMITA'
FCO
FINECORSA OSTACOLO
FCD
FINECORSA DISCESA
D
DIODO 1N 4003
CNF2/3/4 CONNETTORE FEMMINA COLLEG. COLONNE SATELLITI
CNF1
CONNETTORE CANNON 15 POLI FEMM.
INTERCONNESS.COL COM.
C
CONDENSATORE ELETTROLITICO 4700 microF 50V
REF.
DENOMINATIONS
-
TERMINAL
KS
RISE CONTROL CONTACTOR
TR
TRANSFORMER 200VA Vp 0/220/400 Vs 0/18 0/24
KL
LINE CONTACTOR
KD
DESCENT CONTROL CONTACTOR
STM
MOTOR HEAT PROBE
SC
POST SELECTION SWITCH
R4
RESISTOR 1/4W 5,6K
R3
RESISTOR 1/4W 10K
R2
RESISTOR 1/4W 15K
R1
RESISTOR 1/4W 39K
KSF
PHASE SEQUENCE CONTROL RELAY
K4/5
EMERGENCY RELAY
K3
DOWN CONTROL RELAY
K2
UP CONTROL RELAY
K1
MOTOR CONTROL RELAY
PS
UP PUSH-BUTTON
PRD
RECTIFIER JUMPER
PLC
LOGIC PROGRAMMABLE CONTROLLER
PEM
EMERGENCY PUSH-BUTTON (MUSH-ROOM SHAPE)
PD
DOWN BUTTON
P1
SINGLE-MOVEMENT YELLOW PUSH-BUTTON
M
MOTOR
L2
BLOCK AND EMERGENCY RED WARNING LIGHT
L1
CORRECT PHASE SEQUENCE WARNING LIGHT
IG
MAIN INVERTER 1-0-2 (40A)
FU6
PROTECTION FUSE 24Vdc PLC 5x20 1A 250V QUICK
FU5
SECONDARY PROTECTION FUSES TR
(18V) 5x20 4A 250V QUICK
FU4
SECONDARY PROTECTION FUSES TR
(24V) 5x20 4A 250V QUICK
FU3
PRIMARY PROTECTION FUSES TR 10.3x38 10A 500V aM
FU2
TRIPLET OF MOTOR LINE FUSES 10.3x38
16A 500V aM (VERS.230V) 10.3x38 10A 500V aM (VERS.400V)
FU1
TRIPLET OF MOTOR LINE FUSES 14x51 50A 500V aM
(VERS.230V) 14x51 32A 500V aM (VERS.400V)
FCUB
NUT WEAR LIMIT SWITCH
FCS
RISE LIMIT SWITCH
FCP
PROXIMITY LIMIT SWITCH
FCO
OBSTACLE LIMIT SWITCH
FCD
DESCENT LIMIT SWITCH
D
DIODE 1N 4003
CNF2/3/4 FEMALE CONNECTOR TO SATELLITE POSTS
CNF1
CANNON 15-POLE FEMALE CONNECTOR, INTERCONNS.
C
ELECTROLYTIC CAPACITOR 4700 microF 50V
0525-M004-1
1 1
65