◆ Check periodically
• If the unit is used for a long time, parts may deteriorate and cause malfunction or bad drainage of dehumidified
water depending on the heat, humidity, or dust.
• In addition to the usual maintenance, it is recommended that you have the unit checked and maintained by the
dealer where you purchased it.
NOTE
For environmental conservation, it is strongly recommended that the indoor and outdoor units of the air conditioner
in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner.
When the air conditioner is operated for a long time, periodic maintenance (once a year) is recommended.
Furthermore, regularly check the outdoor unit for rust and scratches, and remove them or apply rustproof
treatment, if necessary.
As a general rule, when an indoor unit is operated for 8 hours or more daily, clean the indoor unit and outdoor unit
at least once every 3 months. Ask a professional for this cleaning / maintenance work.
Such maintenance can extend the life of the product though it involves the owner's expense.
Failure to clean the indoor and outdoor units regularly will result in poor performance, freezing, water leakage, and
even compressor failure.
Maintenance List
Part
Unit
Check (visual / auditory)
Heat exchanger
Indoor / outdoor
Dust / dirt clogging, scratches
Fan motor
Indoor / outdoor
Sound
Filter
Indoor
Dust / dirt, breakage
• Vibration, balance
Fan
Indoor
• Dust / dirt, appearance
Air intake /
Indoor / outdoor
Dust / dirt, scratches
discharge grilles
Dust / dirt clogging, drain
Drain pan
Indoor
contamination
Ornamental panel,
Indoor
Dust / dirt, scratches
louvers
• Rust, peeling of insulator
Exterior
Outdoor
• Peeling / lift of coat
69-EN
– 35 –
Maintenance
Wash the heat exchanger when it is clogged.
Take appropriate measures when abnormal
sound is generated.
• Wash the filter with water when it is
contaminated.
• Replace it when it is damaged.
• Replace the fan when vibration or balance is
terrible.
• Brush or wash the fan when it is contaminated.
Fix or replace them when they are deformed or
damaged.
Clean the drain pan and check the downward
slope for smooth drainage.
Wash them when they are contaminated or apply
repair coating.
Apply repair coating.
9

Troubleshooting

Check the points described below before requesting repair.
Symptom
• White, misty, cold air or water comes out.
• Sometimes the noise of air leaking is
Outdoor unit
heard.
• A noise is heard when the power is turned
on.
• Sometimes a swishing is heard.
Indoor unit
• A clacking sound is heard.
• Discharged air smells unusual.
The unit does not run.
The room does not cool down or warm up.
If you find something unusual even after checking the above, stop running the unit, turn off the circuit breaker, and
inform the dealer where you purchased the product of the product number and symptom. Do not attempt to repair
the unit by yourself as doing so is dangerous. If the check indicator (
controller LCD, inform the dealer of its content as well.
If any of the following occur, stop running the unit immediately, turn off the circuit breaker, and contact the dealer
where you purchased the product.
• The switch does not work properly.
• The circuit breaker often blows out.
• You unintentionally put a foreign object or water inside.
• The unit cannot be run even after the cause of the protective device activation is removed.
• Other unusual conditions are found.
Cause
• The fan of the outdoor unit is automatically stopped
and defrosting is performed.
• The solenoid valve works when defrosting starts or
stops.
• The outdoor unit is preparing for running.
• When the unit starts running, during operation, or
immediately after the unit stops running, a sound such
as water flowing may be heard, or the operation sound
may become louder for a couple of minutes
immediately after the unit starts running. This is the
sound of the refrigerant flowing or the dehumidifier
draining.
• This is a sound generated when the heat exchanger,
etc. expands and contracts slightly due to temperature
change.
• Various smells from the walls, carpet, clothes,
cigarette, cosmetics, etc. adhere to the air conditioner.
• Has a blackout occurred?
• Has the circuit breaker blown?
• Has the protective device been activated? (The
operation indicator and
on the remote controller
are blinking.)
• Is the air intake or discharge of the outdoor unit
clogged?
• Is a door or window open?
• Is the air filter clogged with dust?
• Is the air volume set to "Low"? or is the operation
mode set to "Fan"?
• Is the setup temperature appropriate?
,
,
etc.) is displayed on the remote