UK
User instructions
EF 10/20, TI, TID Rapid heater
1. Warnings
You are requested to read carefully all the information in
these instructions Keep these instructions carefully and if
applicable pass them on to the final owner.
In the event of a fault disconnect the electricity supply to
−
the appliance.
−
Where the appliance is out of operation for a long period,
disconnect the electricity supply to the appliance.
−
Repairs to electrical appliances must only be performed
by a competent electrician.
It heater is only suitable for domestic use or similar
purposes within enclosed spaces.
DO NOT COVER THE APPLIANCE or place material or
garments on it, or obstruct the air circulation around this
appliance, for example with curtains or furniture, as this
could cause overheating and a fire risk.
It is particularly important that the appropriate safety
regulations for bathrooms, showers etc. are fulfilled.
heater must be installed so that the switches and
other controls cannot be touched by the person in the bath or
shower.
The installation and electricity supply can only take
place in safety Zone 3 according to VDE 0100 Part 701 .
−
By covering the heater or by placing or moving it within
the specified minimum clearances could cause a heat
build up and possibly lead to material igniting. You must
observe the minimum clearances.
−
No materials can be used in the room where the appliance
is installed whose fumes or the material itself could give
rise to ignition, explosion or thermal decomposition due to
the high temperatures. In such cases (e.g. sticking down
of floor coverings) first ensure that the appliances have
cooled down to room temperature.
Warning : In order to avoid a hazard due to inadvertent
resetting of the thermal cutout, this appliance must not be
supplied through an external switching device, such as a
timer, or connected to a circuit that is regularly switched
on and off by the utility.
The appliance is not intended for use by children or other
persons without assistance or supervision if their physical,
sensory or mental capabilities prevent them from using it
safely. Children should be supervised to ensure that they
do not play with the appliance.
−
No objects should be inserted through the openings of the
appliance, This could lead to functional faults, possibly to
the ignition of the object.
−
Warning!
There may be dangers following the automatic
switching on of connected heaters in your absence,
e.g. heaters which have been moved or covered in the
meantime could cause a fire.
−
The supply cord must not be placed over the hot heater.
2. Description
Type
Heating capacity
EF 10/20
2000W
EF 10/20 TID
2000W with 24-hour timer
EF 10/20 TI
2000 - 1000W with 120 minute timer
Supply voltage :
1 /N/PE~230V 50Hz.
Dimensions:
(BxHxT) 290 x 390 x 120mm
Mounting: vertical on a wall.
The heater is splashproof IP24, construction available Class I
or Class II options please refer to appliance rating label.
3. Minimum clearances, mounting
The rapid heater must only be installed in the vertical position.
The heater must not be located immediately below a fixed
socket outlet.
The minimum clearances given in the diagram must be
observed.
290
250
This
Furthermore, a clearance of at least 750mm is to be main-
tained from the front of the heater. With easily combustible
objects such as curtains or heat sensitive plastic, ensure that
these are not blown upon by the hot air stream.
The heater must be secured to the wall with 2 screws (see
diagram). Use the screws and wall plugs in the enclosed
plastic bag.
Installation
Fix the heater as shown in the diagram.
4. Electrical connection
If the supply cord is damaged, it must be replaced by a
special cord or assembly available from the manaufacturer
or its service agent.
THIS HEATER MUST NOT BE LOCATED IMMEDIATELY
BELOW A FIXED SOCKET OUTLET.
5
453320.66.76 09/10/E
120
300
2
20
1
390
230