CONNECTIONS
DMX512 connection / connection between fixtures
Projector 3
Starting address 49
120 Ohms
The wires must not come into contact with each other; otherwise the fixtures will not work at all, or will not
work properly.
Please note the starting address depends upon which controller is being used.
DMX512 control
A DMX512 data link is required in order to control the device via DMX. The device provides 3-pin XLR
connectors for DMX connection.
1. Connect the output of your DMX controller to the DMX input DMX IN of the device with a DMX cable.
2. Connect the DMX output DMX OUT of the device to the DMX input of the next unit in the chain. Always
connect one output to the input of the next unit until all units are connected. Not suitable as signal
splitter!
3. At the last unit, the DMX cable has to be terminated. Plug the terminator with a 120 Ω resistor between
Signal (–) and Signal (+) in the DMX output of the last unit.
XLR connection:
Wireless DMX transmission with QuickDMX
The device features an alternative DMX input for a QuickDMX receiver (sold separately). This connector
allows for wireless transmission of DMX control signals to the device. The connector is designed as a USB
port which provides the required 5 V operating voltage for the receiver. With QuickDMX devices, extensive
cabling between the DMX controller and the device is not required.
Occupation of the USB port:
Projector 2
Starting address 25
23/32
Projector 1
Starting address 1
DMX-512 Controller
00124465.DOCX, Version 1.0