Terminals
Function
L-N-GND
Power supply
4-5
Flashing light
6-7-8
Motor 2
9-10-11
Motor 1
12-13
ELS/SRL
14-15
24 VAC
16-17
SCA
18-19
2CH/TX.
20-21
Antenna
22
PED
23
Step-by-Step
24
STOP
25
PHOT
26
COM
The control unit is equipped with an built-in radio module for the reception of variable code controls, with ARC (Advanced Rolling-
Code) or fixed code, 433.92 MHz frequency.
F1: F6.3A (230VAC) / F10A (115VAC) – Motor protection
F2: T100mA (230Vac) - T200mA (115Vac) – Protection for primary transformer
1) Cut-off power supply.
2) Manually release the wings, move them to approx. half-stroke and lock them again.
3) Reset power supply.
4) Send a step-by-step control signal by pressing the button ->.
5) The wings should start an OPENING movement.
If this is not the case, invert the movement wires of the motor (9<>11 for motor M1, and 6<>8 for motor M2).
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting the
desired values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software
release.
1 – Press the button <PG>, the display goes to the first menu, Parameters "PAR".
2 – With the <+> or <-> button, select the menu you want.
3- Press the button <PG>, the display shows the first function available on the menu.
4 - With the <+> or <-> button, select the function you want.
5 - Press the button <PG>, the display shows the value currently set for the function selected.
6 - With the <+> or <-> button, select the value you intend to assign to the function.
7 - Press the button <PG>, the display shows the signal "PRG" which indicates that programming has been completed.
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any
changes.
Simultaneously pressing <+> and <-> when the display is switched off shows the card software release.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 30s the control unit quits programming mode and switches off the display.
12
HEADY CONTROL UNIT
INPUT/OUTPUT FUNCTIONS
Input, mains power supply.
HEADY:230VAC 50/60Hz (/1-Phase/2-Neutral 3-GND)
HEADY115: HEADY:230VAC 50/60Hz (/1-Phase/2-Neutral 3-GND)
Connection of flashing light, 230VAC 40W max, or 115VAC 40W max, for HEADY 115.
Connection to motor 2: 6-move/7-Com/8-move)
Connection to motor 1: 9-move/10-Com/11-move)
Normally Open free tension contact for courtesy light or electric lock See TLS parameter
Output, power supply of accessories, 24VAC/0.5A max
N.O. free-tension contact for open gate warning light With open gate the contact is closed,
flashing light during operation and open contact with closed gate.
Output, second radio channel of the integrated receiver or photocell power supply in photo
test mode.
N.O. tension-free contact. See wire diagram, Fig 1.
Connection of extractable radio receiver card to antenna (20-signal/21-monitor).
Input, push-button for pedestrian opening (Normally Open contact) The total opening of motor
1 is carried out.
Input, Step-by-Step push-button (Normally Open contact) See P.P. Logics
Input, STOP push-button (Normally Closed contact)
Input, photocell active in the opening and/or closing phase (Normally Closed contact) See
PHCL Logics
Common, for control inputs.
FUSES
TO CHECK CONNECTIONS:
PROGRAMMING
TO ACCESS PROGRAMMING
NOTES
Description