Instruction Manual
XPR-5590
Please read these instructions before using your Nightstick XPR-5590
They include important safety information and operating instructions.
Model XPR-5590
Bayco Products, Inc.
640 S. Sanden Blvd., Wylie, TX 75098
ID 4001184
WARNING: Risk of ignition - Do not open in a hazardous area.
AVERTISSEMENT: Ne pas ouvrir dans une zone dangereuse.
WARNING: Risk of ignition - Do not charge batteries in a hazardous area.
AVERTISSEMENT: Danger d'inflammation - Ne pas charger les piles dans une
zone dangereuse.
WARNINGS - INTRINSICALLY SAFE
y Warning: To prevent ignition of a hazardous atmosphere, do not attempt to charge
this product in the hazardous environment. This task must ONLY be performed in an
area known to be non-hazardous.
y Warning: Lithium-ion batteries must be used and charged properly. Improper use
can result in serious injury, fire, or death.
y Warning: Use only the included and approved 1514-BATT rechargeable battery pack
from Bayco Products.
y Warning: When exchanging the rechargeable battery pack, use only the approved
1514-BATT rechargeable battery pack from Bayco Products.
y Warning: To prevent ignition of a hazardous atmosphere, the rechargeable battery
pack must only be exchanged in an area known to be non-hazardous.
y Warning: Do not expose the rechargeable battery pack to water or salt water, or
allow the battery pack to get wet.
y Warning: Do not store the rechargeable battery pack with metallic objects that may
cause a short circuit.
y Warning: Substitution of components components is not allowed and may impair
intrinsic safety.
SPECIAL INSTRUCTIONS FOR INTRINSIC SAFETY
For personal safety, always confirm the rating of any known hazardous or potentially
hazardous location where the light is to be used.
INITIAL USE
Warning: To prevent ignition of a hazardous atmosphere, do not attempt
to charge this product in the hazardous environment. This task must ONLY be
performed in an area known to be non-hazardous.
Fully charge the XPR-5590 before the first use, or if the battery is new or has been
unused for several months. The maximum charge time required is approximately 4-6
hours.
Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • 1-800-233-2155 • 1-469-326-9400 • www.nightstick.com
Model XPR-5590
with Case and Tripod
XPR-5590
CLASS I DIV 2 GRPS A-D T3
CLASS II & III DIV 2 GRPS F-G T135°C
CLASS I ZONE 2 Group IIC T3
-20ºC ≤ Tamb ≤ +40ºC
7.4V/Cell 1514-BATT
INS-XPR-5590-MH-19
DAILY USE
WARNING: TO PREVENT IGNITION OF A HAZARDOUS ATMOSPHERE, DO NOT
ATTEMPT TO CHARGE THIS PRODUCT IN THE HAZARDOUS ENVIRONMENT.
THIS TASK MUST ONLY BE PERFORMED IN AN AREA KNOWN TO BE NON-
HAZARDOUS.
y Use only the supplied Nightstick AC, DC adapter, or USB cord. For best performance,
charge the XPR-5590 when the light starts to dim.
y Connect the AC, DC adapter, or USB cord into the bottom of the light.
y The total time to full charge the XPR-5590 varies depending on the remaining charge
in the battery pack.
y In order for the light to be waterproof the rubber plug must be reinserted into the
charging port. (Image 1)
Image 1
SETTING UP THE WORK LIGHT WITH TRIPOD
Opening the tripod leg set:
Fully unfold the Tripod leg set and slide the center collar down until it locks into place.
WARNING: Do NOT attempt to use the tripod leg set unless the legs are fully extended
and locked into place. This is the ONLY position that the leg set can be used in.
Closing the tripod leg set:
Press the release button on the side of the center collar and then raise the center
collar up until the tripod leg set is fully retracted.
Adjusting the column sections:
The tripod has two adjustable sections of the column that can be used to customize
the working height of the work light. Each section is locked into place by means of a cam
lock lever. (Image 2) To adjust the height of either section, release the cam lock lever for
that section, extend the column to the desired length and the re-lock the cam lock lever.
Removing the light head from the tripod:
The NSR-5590 is designed so that the light head can be removed from the tripod.
To remove the light head, grasp the lights handle with one hand, and grasp the top of
the tripod stand with the other hand a pull the magnet apart from the mounting plate.
Installing the light head onto the tripod:
CAUTION: Before installing the light head on to the tripod, be certain that the leg
set is fully extended and locked in place and that both of the two column cam lock
levers are securely locked.
To install the light head on to the tripod, simply line up the light heads magnetic
base with the tripods mounting plate (Image 3) allowing the magnet to secure itself to
mounting plate. Be sure place the light head directly onto the center of the mounting
plate so that the light head is securely mounted.
OPERATION
CAUTION: BECAUSE THE XPR-5590 HAS A MAGNETIC BASE, IT IS LIKELY
THAT IT WILL BE PLACED IN AN ELEVATED POSITION ABOVE THE GROUND.
THEREFORE CAUTION SHOULD BE USED TO BE CERTAIN THAT THE MAGNET
IS SECURELY ATTACHED TO THE METAL SURFACE BEFORE RELEASING THE
LIGHT. IT IS ALSO ADVISED THAT EXTRA CARE BE TAKEN WHEN ADJUSTING
OR MOVING THE CORD SO THAT THE WORK LIGHT DOES NOT COME LOOSE
AND FALL TO THE GROUND.
The XPR-5590 has a single three-position toggle switch with black boot. Operation
as seen from the back of the light:
y Center position:
Off
y Right position:
High-brightness
y Left position:
Low-brightness
WARRANTY
1 YEAR WARRANTY
Bayco Products, Inc. warrants this product to be free from defects in workmanship
and materials to the original purchaser for 1 year from the date of purchase, and includes
the LEDs, housing, lenses, electronics, switches, rechargeable batteries and chargers.
Bulbs (other than LEDs) are covered for 90 days from the date of purchase.
We will repair or replace this product should we determine it to be defective. This is the
only warranty, expressed or implied, including any warranty of merchantability or fitness for
a particular purpose.
For a complete copy of the warranty, go to www.baycoproducts.com/nightstick-
product-support/warranties. Retain your receipt for proof of purchase.
Image 2
Image 3
02-21-2019

Werbung

loading

Inhaltszusammenfassung für Bayco NightStick XPR-5590

  • Seite 1 The maximum charge time required is approximately 4-6 For a complete copy of the warranty, go to www.baycoproducts.com/nightstick- hours. product-support/warranties. Retain your receipt for proof of purchase. Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • 1-800-233-2155 • 1-469-326-9400 • www.nightstick.com INS-XPR-5590-MH-19 02-21-2019...
  • Seite 2: Garantie

    Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • 1-800-233-2155 • 1-469-326-9400 • www.nightstick.com INS-XPR-5590-MH-19 02-21-2019...
  • Seite 3 é de aproximadamente 4-6 horas. superficie metálica antes de soltar la lámpara. También se aconseja que se tome Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • 1-800-233-2155 • 1-469-326-9400 • www.nightstick.com INS-XPR-5590-MH-19 02-21-2019...
  • Seite 4: Erstmaliger Gebrauch

    Energie zuvor noch in der Batteriepackung vorhanden ist. y Damit das Arbeitslicht wasserdicht ist, muss der Gummistöpsel wieder in den Aufladekanal eingeführt werden. (Bild 1) Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • 1-800-233-2155 • 1-469-326-9400 • www.nightstick.com INS-XPR-5590-MH-19 02-21-2019...
  • Seite 5 Gebrauchstauglichkeit und Eignung für den bestimmten Zweck dieses Produktes. Eine vollständige Kopie der Garantie ist auf www.baycoproducts.com/nightstick- product-support/warranties. Bewahren Sie den Kassenzettel zum Kaufnachweis auf. Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • 1-800-233-2155 • 1-469-326-9400 • www.nightstick.com INS-XPR-5590-MH-19 02-21-2019...