Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Characteristics - Beninca ONE.2WI Handbuch

Vorschau ausblenden Andere Handbücher für ONE.2WI:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
LED
Switching
Blinks
Time
1
1s
2
2s
3
3s
4
4s
5
5s
6
6s
7
7s
8
8s
This function is only necessary when one of the two channels
has to be set to be timed (from 1 sec to 10 min) or with bistable
operation. The pulse operating mode is set by default (1 sec
switching). To set the times enter mode 4 (for channel 1) or
mode 5 (for channel 2) and wait until the end of the 5 rapid
blinks. The Times submenu is described in table 2.
Resetting the memory
Cut off the power to the receiver. Press and keep pressed the
button P. Restore the power keeping the button P pressed. The
LED will light up red, after 5 secs it will blink rapidly alternating
green-red, release the button. Wait for the LED to go out. The
memory is now completely erased.
LED
Blinks
9
10
11
12
13
14
15
16
Times Mode
TABLE 3
Switching
LED
Time
Blinks
9s
17
10s
18
30s
19
60s
20
1,5m
21
2m
22
2,5m
23
3m
24

Technical Characteristics

Frequency
Power supply
Range
Channels
Relay contact
Working temperature
Consumption in standby
Consum. ch. 1 or 2 actuated
Consum.ch. 1 and 2 actuated
Switching
LED
Time
Blinks
3,5m
25
4m
26
4,5m
27
5m
28
1m
29
2m
30
3m
4m
ONE.2WB/WI/WO
433,92 MHz
21÷28 Vac
12÷28 Vdc
Without antenna 30m
with antenna 100m
1A/24 Vdc
-20/+70°C
Switching
Time
5m
6m
7m
8m
9m
10m
2
10 mA
42 mA
66 mA
15

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

One.2wbOne.2wo

Inhaltsverzeichnis