1 The Christie Heat Extractor Kit
This document provides information and instructions for installing the Christie heat extractor kit
(P/N: 38-814008-61). Only accredited Christie technicians who are knowledgeable about the hazards
associated with high-voltage, ultraviolet exposure, and the high temperatures generated by the projector lamp
are authorized to assemble, install, and service the projector.
The Christie heat extractor moves air at a minimum rate of 600 cubic feet per minute (CFM); this is the
minimum airflow recommended for all of the listed projectors. The 1.82 meter (6 foot) duct can be used with
all of the listed projectors. However, the shorter 15 centimeter (6 inch) duct is only recommended for use with
Roadie 25K projectors when the projector is installed in a confined space. If the projector is installed in a
confined space and it is operating for extended periods, route the duct to the outside of the building to ensure
optimal airflow. If you are using a longer duct, you must install additional extractors to keep the projector cool.
When installing third party extractors, make sure they meet the minimum requirement of 600 CFM.
If you are stacking Roadie 25K projectors, a side-venting duct adapter (P/N: 108-100101-01) is required.
1.1
Compatibility
The Christie heat extractor is compatible with these projectors:
• Roadie 25K
• Roadie HD+30K/+35K (when the Christie exhaust kit (P/N: 113-107109-xx) is installed)
• CP2000/SB/XB/ZX
• CP2220/30
• CP4220/30
1.2
What's In the Box?
Every Christie heat extractor kit (P/N: 38-814008-61) includes these parts:
• 1.82 meters (6 feet) OR 15.24 centimeters (6 inches) corrugated exhaust hose
• Extractor
• 3 wire safety cables
• 6 snap hooks (carabiners)
• 4 extractor couplers (attached to the exhaust hose)
• 4 ring couplers (attached to the exhaust hose)
If you are missing parts from your Christie heat extractor kit, contact Christie support.
The Christie Heat Extractor Kit User Manual