PUTTING INTO OPERATION: ADJUSTMENTS
There are two controls on the MULTIMAT sphere:
DELAY TIME
ADJUSTMENT
ADJUSTING THE DETECTION FIELD
The head is able to rotate horizontally by approximately 180º (do not
attempt to force rotation beyond 180º) and vertically by approximately 45º,
thus moving the detection area as shown in the figure:
The detection field can be adjusted by following these steps:
-
Rotate the switch-off delay adjustment to minimum and the ambient
light level adjustment to (☼).
-
Check coverage by moving within the detection field limits.
After installation and detection field adjustments, set the ambient light
level and switch-off delay as required.
The MULTIMAT is supplied with detection area limiters. Each limiter is
divided into four sectors that can be cut according to needs. A sector is
excluded by covering the corresponding part of the lens with limiter
adapted to the actual requirements.
ADJUSTING AMBIENT LIGHT LEVEL
The MULTIMAT can be adjusted so that it only operates when ambient
light level conditions are below the selected level. By rotating the ambient
light level control to position (☼), it will react under any lighting conditions.
Setting it to position (  ) will mean it only reacts under very low ambient
light level conditions.
When the ambient light level conditions are those desired for detection
operation, rotate the ambient light level control to position (  ). Then rotate
it slowly to the right until the illumination comes on. When the MULTIMAT
is ready to detect (the ambient light level is below the adjusted value), the
internal LED will flash every three seconds.
For the changes made to take effect in the potentiometers in the
adjustment of the equipment, it is necessary to get out from the
detection area and wait for the installation to be turned off.
ADJUSTING THE SWITCH-OFF DELAY
By rotating the control (  ), the switch-off delay is as follows:
-
Minimum switch-off delay time: 3 seconds
-
Maximum switch-off delay time: 30 minutes.
This time is reset for each detection operation.
Detection sensitivity may be reduced if the temperature of the object
to be detected is close to the ambient temperature.
When the MULTIMAT delay time ends, there is a two-second period
of inactivity during which it does not detect.
AMBIENT LIGHTING
LEVEL ADJUSTMENT
DETECTION FIELD
LIMITER
BLOCKED DETECTION
FIELD
OPERATING MODE
- The unit enters normal operation thirty seconds after being switched
on.

TECHNICAL SPECIFICATIONS

Power supply
Breaking power
Maximum recommended loads
Incandescent lamps
Fluorescent tubes
Low voltage halogen (12 Vac)
Halogen (230 Vac)
Low consumption lamps (CFL)
Low consumption lamps (Downlights)
Led lamps
Power consumption
Ambient lighting level range
Timer range
Detection angle
Detection field
Operating temperature
Protection type
Protection class
DIMENSIONS
72
06/01.2019
ORBIS TECNOLOGIA ELECTRICA, S.A.
Lérida, 61
Teléfono: +34 91 5672277;
230 V 50 Hz.
10 A 230 V~ cos  =1
μ
2000 W
1200 VA
1200 VA
2000 W
1200 VA
1200 VA
400 VA
8.5 VA (1.5 W approx.)
5-30-2000 Lux.
from 3 s to 30 min. approx.
200º
Front: 12 metres to 20 ºC.
Lateral: 8 metres to 20 ºC.
-20 ºC to +40 ºC
IP 55 by EN 60529.
Class II by EN 60669
under correct installation
conditions.
133
A016.13.54464
E-28020 MADRID
Fax: +34 91 5714006
E-mail: info@orbis.es
http://www.orbis.es