2.5 CH1/CH2 Parallel mode
Instruction
In the parallel mode, CH1 and CH2 are linked internally into one channel which is controlled
by CH1. Its output current value is twice as much as the single channel.
Output rating
0~32V/0~6.4A
Operation steps:
1. Press the "Para" button to start Parallel mode, the indicator light turns bright immediately
and the logo "
2. Connect the load to the positive and negative terminal of CH1.
3. Set voltage and current value:
a) Press "1" button to select the channel 1
b) Move the cursor through direction button to select the required parameter(voltage,
current),
c) Press "Fine" to select the digit position and then revolve the multi-function knob to
change the corresponding parameter.
4. Press "on/off" button corresponding CH1 to turn on the output
Note: You can identify the current working state "CC" or "CV" by referring to indicator light of
CH1/CH2.(red means CV, green means CC).
In parallel mode, CH2 only works in CC mode.
20
"display at the top of screen.