Models 1400, 1442, 1442E, 1444, 1444E
PowerLuber Grease Gun
Condition
Motor fails to run.
PowerLuber fails to
dispense grease.
PowerLuber continues
to lose prime.
Battery fails to take
a charge.
Page Number - 14
TROUBLESHOOTING
Possible Cause
- Battery needs charging.
- Faulty wiring to motor.
- Circuit Breaker
- Grease tube assembly is out of grease.
- Loss of prime.
- Ball check item 19 is not functioning.
- Air may be trapped in several locations
in container after bulk filling.
- Follower may be binding in grease
tube assembly.
- Charger may not have power.
- Battery may be bad.
Corrective Action
Recharge battery.
Remove battery, disassemble
handle and check wiring
for loose connection.
Reset Circuit Breaker.
Check that grease tube
assembly has grease.
Repeat priming operation.
Remove Item 19, clean and
inspect ball seat area.
Empty grease tube
assembly, refill and repeat
priming instructions.
*Replace grease tube assembly
Item 2.
*Disassemble grease tube
assembly and clean.
*Be sure that follower has properly
entered the grease cartridge.
Or
Verify that the follower is not
caught on the rim of the grease
cartridge.
Check that receptacle has power.
Replace battery.
Form 404088