DIP Switch Tables
DIP switch 1 (Serial Interface)
SW
1-1
1-2
1-3
1-4
1-5
1-6
1-7
1-8
Table A
Transmission speed (bps)-bits
per second
Adjustable by control
commands*
4800
9600
19200
* Only when DIP Switches 1-7 and 1-8 are on, the transmission speed can be selected from one of seven
speeds: 2400, 4800, 9600, 19200, 38400, 57600, and 115200 bps by control commands. The default is
38400.
DIP switch 1 (Parallel/USB Interface)
SW
1-1
1-2
*1
1-3
*1
1-4
1-5~
1-7
*2
1-8
*1: For USB I/F, DIP Switches 1-3 and 1-4 are Undefined.
*2: For Parallel I/F, DIP Switch 1-8 is Undefined.
iv
Function
Data receive error
Receive buffer
capacity
Handshaking
Data word length
Parity check
Parity selection
Transmission speed (See table A.)
Function
Auto line feed
Receive buffer
capacity
Select paper sensors to
output paper-end
signals (default value
of a command) from
parallel I/F.
Error signal output from
parallel I/F
Power saving function
for USB
ON
Ignored
45 bytes
XON/XOFF
7 bits
Enabled
Even
SW1-7
ON
OFF
ON
OFF
ON
Always enabled
45 bytes
Disabled
Disabled
Undefined
Disabled
OFF
Prints "?"
4 KB
DTR/DSR
8 bits
Disabled
Odd
SW1-8
ON
ON
OFF
OFF
OFF
Always disabled
4 KB
Roll Paper end sensor
enabled, Roll Paper
near-end sensor
enabled
Enabled
Enabled