proliferation of bacteria that is harmful to health. Parts left to dry with residual
detergent of disinfectant may be damaged.
Remove any elements such as sponges, clothes, detergent residue, or water
from the floor that could cause slipping and accidental falls.
19_9.Parts inspection
Once cleaning, disinfection, rinsing, and drying operations have been completed,
carefully check that all the parts are perfectly clean and dry and have not been
damaged or excessively worn. If necessary, replace them.
Attach the elements once perfectly dry and restore the electrical power supply. Once
internal operating temperature has been reached, the unit can be loaded with the
products to be displayed.
20.Dismantling the unit - specialised technician -
The unit must be disposed of in accordance with your country's waste management
legislation and in respect of our environment. This product is considered by current
legislation as hazardous waste. It must therefore be collected separately and cannot
be treated as household waste nor sent to a landfill. Before disposing of the unit, the
coolant must be collected and the lubricant oil removed. This product consists of 75%
recyclable materials. Materials used in construction:
- Pipes, sections and iron plates:lower frame, risers and shelves
- Copper, Aluminium:
- Iron plate - galvanised:
- Polyurethane foam (R134a): thermal insulation
- Tempered glass:
- Wood:
- ABS:
- Polystyrene:
- Polycarbonate:
- Methacrylate
The user is responsible for delivering the product for disposal to the collection
centre specified by the local authorities or manufacturer for the recovery and
recycling of materials.
All these operations, as for transport and waste processing, should be
performed by authorised, specialised personnel only.
This product contains HFC, a coolant with a high greenhouse effect potential
(GWP). ARNEG uses the following types of coolant in models produced with
built-in refrigeration units:
R 134a; GWP
R 404A; GWP
belonging to the HFC family, namely hydrofluorocarbon gases with a high
global warming potential (GWP), governed by the Kyoto protocol. (Check
which of these two gases is in the appliance by reading the plate or adhesive
label on the device) therefore:
THE COMPONENTS OF THE REFRIGERATION CIRCUIT SHOULD NEVER
BE CUT AND/OR SEPARATED. THEY MUST BE RETURNED INTACT TO A
CENTRE SPECIALIZING IN THE RECOVERY OF COOLANT.
This appliance is hermetically sealed and the coolant load is less than 3
kg.
It is therefore not subject to an obligatory system manual, nor regular
inspections for loss of coolant (Italian Presidential Decree no. 147 of
February 15, 2006, articles 3 and 4).