ELECTRICAL CONNECTION
POWER
WORK
1 2 3 4 5 6 7 8 9 10 11 12
A1
A2
START
STOP
START P.
PHOTO
L1 L2
L3 L4 L5 L6 L7 L8 L9 L10 L11
A1
Antenna
A2
Antenna shield
L1
Opening command for a standard connection device
with switch normally open.
L2
Pedestrian opening command for a standard
connection device with switch normally open.
L3
STOP command. N.C. switch
L4
Photocell. N.C. switch
L5
Edge. Switch N.C. or resistive rubber edge
L6
Commands common (-) line
L7 - L8
24 VAC power output for photocells and other
accessories
L8 - L9
Power supply for functional test TX photocell
L10 - L11 12V electric lock
PAUSE
DELAY
overload
EDGE
K1 K2 K3 K4 K5 K6 K7 K8 K9 K10
M1
K1 - K2
Courtesy light timer activation switch
K3
Motor 1 open
K4
Motor 1 common
K5
Motor 1 close
K6
Motor 2 open
K7
Motor 2 common
K8
Motor 2 closed
K9 - K10
230V - 40W / 120V - 40W blinker
N
230V / 120V power supply - neutral
L
230V / 120V power supply - phase
m
PLEASE NOTE: If not used, the normally closed
inputs (STOP, PHOTO, EDGE) must be jumpered with the
commands common line COM (-)
- 10 -
N mains L
M2
mains