Herunterladen Inhalt Inhalt Diese Seite drucken

Introduction - Purpose Of The Manual/Application Field; Presentation - Declared Use (Fig. 1); Regulations And Certifications; Identification - Plate Data (Fig. 2) - Arneg Perth 5 Installations- Und Gebrauchshandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 37

1. Introduction - Purpose of the manual/Application field

This instruction manual refers to the Perth 5 refrigerated cabinets line.
The information that follows provides indications relating to:
Use of the cabinet - technical features- installation and assembly - information for the operator in charge of
use - maintenance interventions.
This manual is to be considered part of the cabinet and must be preserved for its entire duration.
The manufacturer cannot be held responsible for:
Improper use of the cabinet - incorrect installation not carried out in compliance with the standards indicated
- electric power supply faults - lack of envisioned maintenance - unauthorised modifications and interventions
- use of non original spare parts - partial or total failure to comply with the instructions.
This manual must be available at all times for consultation by the operators and the staff in charge of
maintenance. In case of transfer to third parties, this manual must be passed to the new user or owner. The
supplier must also be informed of the transfer.
In case of damage or loss, request a copy from the manufacturer.
N.B.Electric appliances may be dangerous to health. Regulations and existing laws in force must be
respected during installation and use.
This manual must be read by anyone using this cabinet.

2. Presentation - Declared use (Fig. 1)

The Perth 5 refrigerated cabinets line consists in vertical wall cabinets, with a remote condensing unit,
suitable for preserving and self service Frozen products and Ice-creams.
The cabinet is made up from two independent units; a lower cabinet (tank) open in the upper part and an
upper cabinet (superstructure) with many shelves, closed in the front by doors.
The two parts have their own evaporator and separate air control system.
To ensure maximum energy saving and improved preservation of foodstuffs, the Perth5 completes
its family with the Pelican with glass closing device on the tank.

3. Regulations and certifications

The regulations according to which the cabinet has been tested and approved are:
EN-ISO 23953 - 1/2; EN 60335-2-89; EN 61000-3-2; EN 61000-3-3; EN 55014
Environment climatic categories
These cabinets have been checked respecting climatic category 3 (25°C;H.R.60%):
The cabinets conform to the essential requisites requested by the following directives:
Climatic Category
Dry bulb temperature
1
2
3
4
5
6
- Machine Directive 98/37 EEC;
- Electromagnetic compatibility directive 89/336 CE including last modifications 92/31 EEC, 93/68 EEC;
- Low Voltage Directive 2006/95/CE.
It is excluded from the application field of the EEC 97/23 (PED) directive by virtue of Art.1 paragraph 3.

4. Identification - Plate data (Fig. 2)

On the back of the cabinets a plate with the following characteristics data is present:
1. Name and address of the manufacturer
2. Name and length of the cabinet
3. Cabinet code number
4. Cabinet serial number
5. Supply voltage
6. Power frequency
7. Input current
8. Electric power absorbed during the refrigeration phase (Compressors + fans + hot cables)
9. Electric power input during the defrost phase (Evaporator fan hot cables)
10. Lighting power (where foreseen)
05060095 00 30/01/2009
Relative Humidity
16°C
80%
22°C
65%
25°C
60%
30°C
55%
40°C
40%
27°C
70%
Dew point
12°C
15°C
17°C
20°C
24°C