ENG
If the ICM is not functioning properly or is out of order, please check the following
before calling the authorized service provider:
FAULT
POSSIBLE REASONS
Power cord not plugged in.
No power coming through the
socket.
The ICM has recently been
reloaded with warm products.
It takes 8-16 hours to cool
them down.
The ICM is loaded in such a
The ICM does not
way that the air circulation in
work.
the interior is getting blocked.
The door does not seal
properly.
Leakage in the cooling system.
For this particular ice cold
merchandiser, a powerful
mechanism is needed and
consequently a certain
amount of noise cannot be
The ICM
avoided.
sometimes
Intense metallic noise.
makes noise.
Inclined or curved floor.
14
UNPLUG THE COOLER PRIOR TO ANY MAINTENANCE
OR SERVICE OPERATIONS. REMOVE THE PLUG AND
MAKE SURE THAT THE OPERATOR CAN CHECK FROM
ANY OF THE POINTS WHICH THEY HAVE ACCESS
THAT THE CABLE IS UNPLUGGED.
After maintenance operations, make sure that the
grounding connections are in place before assembling
the covers. Make sure you use the same fastening
components and covers.
If any electrical components need to be replaced, use
only the identical components in the spare part list
supplied by the technical service department of
Frigoglass.
Keep the glass door on the back side of the cooler
closed during maintenance. The appliance will not stand
stable when the compressor is disassembled. If the
compressor needs to be replaced, use adequate support
on the front side of the cooler.
After maintenance operations make sure that the strain
relief, which supports the supply cord, is assembled
properly.
HANDLING
Plug it in.
Check for fuse/MCB on the
mains.
Preferably, reload the ICM
before night closing.
Load the ICM according to the
standards you have been
provided with by the company.
Repair the doors for proper
closing (this type of repair
should be performed by an
authorised technician).
Repair the leakage (This type of
repair should be performed by
an authorized technician).
Ice Cold Merchandisers are
of dynamic type, according
to the specifications that the
company is offering.
Call a Service technician.
Level the ICM properly by
adjusting its feet. Placing a spirit
level on the top of the ICM will
assist you in leveling it.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis