Personal safety

Personnel that uses or assists in the use of the equipment must wear all personal means of protection
as prescribed in the standard work procedure. Negligent use of personal means of protection can result
in serious injury. During use wear at least the following personal means of protection:
Helmet;
Safety goggles or full face shield;
Safety gloves;
Safety clothing for the entire body;
Safety shoes with good ankle support and toe protection.
2.5
Safety regulations with respect to the equipment
Use a regulator to control the air source for a maximum operating pressure of 12 bar.
Do not connect compressed air if any oil or grease is present. Oil and grease is explosive in the
vicinity of compressed air.
Do not stay in line with the air stream.
The body of this control device can get very cold when deflating lifting bags.
Always use cribbing when lifting objects.
Never place more than 2 lifting bags upon another.
Always make sure the lifting bag system is properly connected before proceeding operating any
control device.
Never change the settings of any safety device.
2.6
Safety regulations with respect to maintenance
Wear personal means of protection when performing maintenance tasks.
Never work in a way that could jeopardize safety.
Make sure that the equipment cannot roll away or tip over. The control and drive must be switched
off and safeguarded against unexpected activation.
Make sure that moving parts do not move unexpectedly.
Used or leaked fluids, and any other products consumed during the activities, must be collected and
disposed of in a environmentally responsible way.
3
Description
3.1
Equipment
The control is suitable for a maximum system operating pressure of 12 bar.
The control device is equipped with a three-way valve with automatic return to "0" position, suitable for
operating lifting bags.
Safety valves protect the lifting bags against overload. The safety valve discharges the air at a pressure
of approximately 12.5 bar.
3.2

Type designation

Example: SCV 12