Problem
Water leaks from junction of attachments.
Cause
Junction seal worn or leaky.
Remedy
Check, clean and lubricate seals. Replace if necessary.
Problem
Attachments do not fit perfectly.
Cause
Dirt has accumulated in the junctions and rapid couplings.
Remedy
Clean and lubricate junctions and rapid couplings.
Problem
Suction is not working.
Cause
The wet vacuum plug is not inserted into the socket on the
control panel.
Switch of the wet/dry vacuum head in pos. "0"
Remedy
Check the wet vacuum plug is correctly inserted into the so-
cket on the control panel.
Place the switch of the wet/dry vacuum head in pos. "I"
If the problem persists, contact the service centre.
Problem
No steam is being delivered.
Cause
Boiler not yet up to pressure ("E" indicator light out).
No voltage.
When the water tank is empty, the light "D" comes on (continu-
ous beep emitted) when the steam switch is operated.
Steam switch not activated.
Remedy
Wait a couple of minutes until the "E" light on the panel goes out.
If the problem persists, contact the service centre.
Check there is voltage. Check the appliance is plugged in
correctly.
Add clean water to the water tank.
Make sure the switches are activated.
Problem
No steam is delivered and the pump continues to work.
Cause
Air has got into the boiler feed circuit.
The water filter of recharge pump is clogged.
Remedy
Avoid waves in the water in the tank. Make sure the intake is
below the level of the water.
Clean the water filter placed at the recharge pump inlet
Reset normal washing cycle.
If the problem persists, contact the service centre.
English
Problem
Drops of water are discharged from the attachments.
Cause
For the first few minutes of use, it is normal for condensation to
form due to the difference in temperature between the attach-
ment and the steam.
Remedy
After several minutes use, the problem will be resolved auto-
matically. If it persists, clean boiler.
Problem
"D" pilot light on the control panel is on and the steam switch is
operated. (continuous beep emitted).
Cause
No water in the tank.
Remedy
Add clean water to the water tank.
For maintenance and/or repairs, use only original spare
parts which offer the greatest characteristics of quality and
reliability. Failure to use original spare parts absolves the
manufacturer from all liability and transfers it to the person
carrying out the operation.