9.5. Trouble Shooting and Remedy

In case of errors/troubles not mentioned above, please contact your local service technician for further assis-
tance.

9.6. Service address

Please see the back cover of this manual
Symptoms
The unit does not start
The "Δ" lamp on the controlpanel is
flashing
No pressure/too low pressure
Possible Causes
Is there voltage to the unit
Fuse blown
Display lights up, but the unit
does not start after reconnect-
ing voltage
Unit starts after changing
startup method
After reactivating flow start
Error messages on display
Error after restart
Insufficient or No water supply
Is the filter if any clogged
Is the pump leaking or making
jarring sounds
Rinsing nozzle not installed
Remedy
Reconnect voltage
Call technician
Go to setup -> Settings menu
-> Startup method,
and set it to pressure
Set unit back to flow start in
setup menu
Try to re-adjust flow switch
Press "0" wait for a few sec-
onds and then press "1"on
the control panel to restart the
system.
Go to software manual
Open water supply valve
Clean the filter
Call technician
Place rinsing nozzle