8. Fault finding chart

PROBLEM
Pump does not start
Pump does not deliver
Insufficient delivery
Pump stops after a short
interval
The pump vibrates and
is too noisy
PROBABLE CAUSE
No power supply
Automatic switch tripped or blown
fuses
Overload protection
Impeller jammed
There is air in the system and in the
pump body
Incorrect direction of rotation
Pump or pipes obstructed
Pump runs beyond rated capacity
Overload protection trips
The pump does not rotate freely
Liquid is too viscous
Worn ball bearings
The pump is cavitating
Foreign matter inside the pump
POSSIBLE REMEDIES
Supply electrical power
Re-set the switch and replace the
fuse
Re-set the protection
See point 6.2
Bleed the system and prime the
pump (see point 6.2)
See point 6.1
Disassemble and/or clean
Partially close the delivery gate valve
Replace bearings
See paragraph 6.2
Disassemble and/or clean